Page 8
Electrical Characteristics
Bus Hold Specifications
lists the Arria V device bus hold specifications. The bus-hold trip points are
based on calculated input voltages from the JEDEC standard.
Table 7. Bus Hold Parameters for Arria V Devices
V
CCIO
(V)
Parameter Symbol
Conditions
Min
Bus-hold,
low,
sustaining
current
Bus-hold,
high,
sustaining
current
Bus-hold,
low,
overdrive
current
Bus-hold,
high,
overdrive
current
Bus-hold
trip point
V
IN
> V
IL
(max.)
1.2
Max
Min
1.5
Max
Min
1.8
Max
Min
2.5
Max
Min
3.0
Max
Min
3.3
Max
Unit
I
SUSL
8
—
12
—
30
—
50
—
70
—
70
—
µA
I
SUSH
V
IN
< V
IH
(min.)
–8
—
–12
—
–30
—
–50
—
–70
—
-70
—
µA
I
ODL
0V < V
IN
<
V
CCIO
—
125
—
175
—
200
—
300
—
500
—
500
µA
I
ODH
0V < V
IN
<
V
CCIO
—
—
-125
—
-175
—
-200
—
-300
—
-500
—
-500
µA
V
TRIP
0.3
0.9
0.375
1.125
0.68
1.07
0.7
1.7
0.8
2
0.8
2
V
Arria V GX, GT, SX, and ST Device Datasheet
December 2013 Altera Corporation