Signal Description  
2.2  
PCI Express* Interface  
Table 2-2.  
PCI Express* Signals  
Name  
Type  
Description  
PETp1, PETn1  
PERp1, PERn1  
PETp2, PETn2  
PERp2, PERn2  
PETp3, PETn3  
PERp3, PERn3  
PETp4, PETn4  
PERp4, PERn4  
PETp5, PETn5  
PERp5, PERn5  
O
I
PCI Express* Differential Transmit Pair 1  
PCI Express Differential Receive Pair 1  
PCI Express Differential Transmit Pair 2  
PCI Express Differential Receive Pair 2  
PCI Express Differential Transmit Pair 3  
PCI Express Differential Receive Pair 3  
PCI Express Differential Transmit Pair 4  
PCI Express Differential Receive Pair 4  
PCI Express Differential Transmit Pair 5  
PCI Express Differential Receive Pair 5  
O
I
O
I
O
I
O
I
PETp6/  
GLAN_TXp,  
PETn6/  
PCI Express Differential Transmit Pair 6: The differential pair will  
function as the Gigabit LAN Connect Interface transmit pair when the  
integrated Gigabit LAN controller is enabled.  
O
I
GLAN_TXn  
PERp6/  
GLAN_RXp,  
PERn6/  
PCI Express Differential Receive Pair 6: The differential pair will  
function as the Gigabit LAN Connect Interface receive pair when the  
integrated Gigabit LAN controller is enabled.  
GLAN_RXn  
2.3  
LAN Connect Interface  
Table 2-3.  
LAN Connect Interface Signals  
Name  
Type  
Description  
Gigabit LAN Input Clock: Clock driven by the Platform LAN Connect  
device. The frequency will vary depending on link speed.  
GLAN_CLK  
I
NOTE: The clock is shared between the LAN Connect Interface and the  
Gigabit LAN Connect Interface.  
Received Data: The Platform LAN Connect device uses these signals  
to transfer data and control information to the integrated LAN  
controller. These signals have integrated weak pull-up resistors.  
LAN_RXD[2:0]  
I
48  
Datasheet