Errors  
6.1.1.2  
Errors during Channel Operation  
Table 6-2.  
Link Errors in Normal Operation (Sheet 1 of 2)  
Error  
Response  
CRC Error on SB frame  
“A” Command - detected by 14-bit CRC (or  
reduced 10-bit CRC in Fail Over mode)  
If CMDCRC error type enabled in EMASK Register  
1.  
2.  
3.  
4.  
5.  
No command executed  
120-bit Raw SB Frame captured in RECFBD Error Log Registers  
Type of error logged in FERR/NERR registers  
Error/Alert Asserted bit set in FBD Status 0 register  
Ignore future commands except Soft Channel Reset until Soft Channel Reset or  
Link Reset Received  
Alert Frame sent continuously starting with NB frame in which returned data  
pattern would be sent if aborted command had been a config read. Alert  
patterns continue until Soft Channel Reset or Link Fast Reset received.  
or  
CRC Error on SB data or “BC” Commands  
in Command Frame - detected by 22-bit  
CRC (or reduced 10bit CRC in Fail Over  
mode  
6.  
Note: Will NOT close DRAM pages or place DRAM into Self Refresh until detection  
of Link Reset.  
Else ignore error  
Lose transition density on channel as  
detected by no Sync in within 2 times the  
SYNCTRAININT value (typically last 84  
frames).  
Note: Purpose of this error is not to  
detect violation of required  
If FEWEDGES error type enabled in EMASK Register  
1.  
2.  
3.  
4.  
5.  
6.  
No command executed in expected Sync slot  
120 bit Raw SB Frame captured in RECFBD Error Log Registers  
Type of error logged in FERR/NERR registers  
Error/Alert Asserted bit set in FBD Status 0 register  
DDR Self Refresh FSM triggered to put DRAMs into Self Refresh  
Ignore future commands including Soft Channel Reset until Link Reset  
Received  
Alert Frame sent continuously starting with NB frame in which returned data  
pattern would be sent if aborted command had been a config read. Alert  
patterns continue until Link Fast Reset received.  
transition density (6 out of 512)  
but to detect hang in the host and  
put DRAM into self refresh. Any  
corruption caused by lack of  
transitions will be detected by  
CRC violations.  
7.  
Else ignore error  
Write Buffer Overrun  
Write data received when FIFO is full  
Overwriting the write buffer is a host error. The AMB does not take any action based  
on an overrun. DRAM writes will proceed. What data item is written following an  
overrun condition is not defined.  
An overrun could be the result of channel errors, but these errors are detectable by  
other means. Detection of an overrun condition is not required, but may be done by  
implementation dependent means for debug.  
Write Buffer Underrun:  
not enough valid entries in Write FIFO to  
support write data to memory  
Underrunning the write buffer is a host error. The AMB does not take any action  
based on an underrun. DRAM writes will proceed. What data item is written  
following an underrun condition is not defined.  
An underrun could be the result of channel errors, but these errors are detectable  
by other means. Detection of an underrun condition is not required, but may be  
done by implementation dependent means for debug.  
72  
Intel® 6400/6402 Advanced Memory Buffer Datasheet  