Boxed Processor Specifications  
Figure 21.  
Baseboard Power Header Placement Relative to Processor Socket  
R110  
[4.33]  
B
C
7.3  
Thermal Specifications  
This section describes the cooling requirements of the fan heatsink solution utilized by  
the boxed processor.  
7.3.1  
Boxed Processor Cooling Requirements  
The boxed processor may be directly cooled with a fan heatsink. However, meeting the  
processor's temperature specification is also a function of the thermal design of the  
entire system, and ultimately the responsibility of the system integrator. The processor  
temperature specification is in Chapter 5. The boxed processor fan heatsink is able to  
keep the processor temperature within the specifications (see Table 26) in chassis that  
provide good thermal management. For the boxed processor fan heatsink to operate  
properly, it is critical that the airflow provided to the fan heatsink is unimpeded. Airflow  
of the fan heatsink is into the center and out of the sides of the fan heatsink. Airspace  
is required around the fan to ensure that the airflow through the fan heatsink is not  
blocked. Blocking the airflow to the fan heatsink reduces the cooling efficiency and  
decreases fan life. Figure 22 and Figure 23 illustrate an acceptable airspace clearance  
for the fan heatsink. The air temperature entering the fan should be kept below 38 °C.  
A Thermally Advantaged Chassis with an Air Guide 1.1 is recommended to meet the 38  
°C requirement. Again, meeting the processor's temperature specification is the  
responsibility of the system integrator.  
Note:  
The processor fan is the primary source of airflow for cooling the VCC voltage regulator.  
Dedicated voltage regulator cooling components may be necessary if the selected fan is  
not capable of keeping regulator components below maximum rated temperatures.  
Datasheet  
93  