Boxed Processor Specifications  
8.3.2.1  
1U Passive/2U Active Combination Heat Sink Solution (1U Rack  
Passive)  
In the 1U configuration it is assumed that a chassis duct will be implemented to provide  
sufficient airflow to pass through the heat sink fins. Currently the actual airflow target  
is within the range of 15-27 CFM. The duct should be designed as precisely as possible  
and should not allow any air to bypass the heat sink (0” bypass) and a back pressure of  
0.38 in. H2O. It is assumed that a 40°C TLA is met. This requires a superior chassis  
design to limit the TRISE at or below 5°C with an external ambient temperature of 35°C.  
Following these guidelines will allow the designer to meet Thermal Profile B and  
conform to the thermal requirements of the processor.  
8.3.2.2  
1U Passive/2U Active Combination Heat Sink Solution (Pedestal  
Active)  
The active configuration of the combination solution is designed to help pedestal  
chassis users to meet the thermal processor requirements without the use of chassis  
ducting. It may be still be necessary to implement some form of chassis air guide or air  
duct to meet the TLA temperature of 40°C depending on the pedestal chassis layout.  
Also, while the active thermal solution is designed to mechanically fit into a 2U  
volumetric, it may require additional space at the top of the thermal solution to allow  
sufficient airflow into the heat sink fan. Therefore, additional design criteria may need  
to be considered if this thermal solution is used in a 2U rack mount chassis, or in a  
chassis that has drive bay obstructions above the inlet to the fan heat sink. Use of the  
active configuration in rackmount chassis is not recommended.  
It is recommended that the ambient air temperature outside of the chassis be kept at  
or below 35°C. The air passing directly over the processor thermal solution should not  
be preheated by other system components. Meeting the processor’s temperature  
specification is the responsibility of the system integrator.  
8.3.2.3  
2U Passive Heat Sink Solution (2U+ Rack or Pedestal)  
A chassis duct is required for the 2U passive heat sink. In this configuration the thermal  
profile (see Section 6) should be followed by supplying 27 CFM of airflow through the  
fins of the heat sink with a 0” or no duct bypass and a back pressure of 0.182 in. H2O.  
The TLA temperature of 40°C should be met. This may require the use of superior  
design techniques to keep TRISE at or below 5°C based on an ambient external  
temperature of 35°C.  
8.4  
Boxed Processor Contents  
A direct chassis attach method must be used to avoid problems related to shock and  
vibration, due to the weight of the thermal solution required to cool the processor. The  
board must not bend beyond specification in order to avoid damage. The boxed  
processor contains the components necessary to solve both issues. The boxed  
processor will include the following items:  
• Dual-Core Intel Xeon Processor 5000 series  
• Unattached Heat Sink Solution  
• 4 screws, 4 springs, and 4 heat sink standoffs (all captive to the heat sink)  
• Thermal Interface Material (pre-applied on heat sink)  
• Installation Manual  
• Intel Branding Logo  
Dual-Core Intel® Xeon® Processor 5000 Series Datasheet  