 浏览型号TP8044AH-R0117的Datasheet PDF文件第37页浏览型号TP8044AH-R0117的Datasheet PDF文件第38页浏览型号TP8044AH-R0117的Datasheet PDF文件第39页浏览型号TP8044AH-R0117的Datasheet PDF文件第40页浏览型号TP8044AH-R0117的Datasheet PDF文件第42页浏览型号TP8044AH-R0117的Datasheet PDF文件第43页浏览型号TP8044AH-R0117的Datasheet PDF文件第44页浏览型号TP8044AH-R0117的Datasheet PDF文件第45页  
IA8044/IA8344  
Data Sheet  
SDLC Communications Controller  
March 30, 2010  
Table 38. Transmit Control Byte Register  
7
6
5
4
3
2
1
0
TCB.7 TCB.6 TCB.5 TCB.4 TCB.3 TCB.2 TCB.1 TCB.0  
4.10.9 Receive Buffer Start Address Register (RBS)  
Table 39 presents the Receive Buffer Start Address Register, which contains the address in  
internal RAM where the frame (starting with the I-field) being received is to be stored. The CPU  
should write RBS only when the SIU is not receiving a frame, RBE = 0. RBS is byte addressable.  
Table 39. Receive Buffer Start Address Register  
7
6
5
4
3
2
1
0
RBS.7 RBS.6 RBS.5 RBS.4 RBS.3 RBS.2 RBS.1 RBS.0  
4.10.10 Receive Buffer Length Register (RBL)  
Table 40 presents the Receive Buffer Length Register, which contains the length, in number of  
bytes, of the I-field storage area in internal RAM. RBL = 0 is valid (no I-field). The CPU should  
write RBL only when the SIU is not receiving a frame, RBE = 0. The receive buffer will not wrap  
around after address 191 (BFH). A buffer end is automatically generated when address 191 is  
reached. RBL is byte addressable.  
Table 40. Receive Buffer Length Register  
7
6
5
4
3
2
1
0
RBL.7 RBL.6 RBL.5 RBL.4 RBL.3 RBL.2 RBL.1 RBL.0  
4.10.11 Receive Field Length Register (RFL)  
Table 41 presents the Receive Field Length Register, which contains the length, in number of  
bytes, of the I-field of the frame received and stored in internal RAM. RFL = 0 is valid (no  
I-field). The CPU should access RFL only when the SIU is not receiving a frame, RBE = 0. RFL  
is loaded by the SIU. RFL is byte addressable.  
Table 41. Receive Field Length Register  
7
6
5
4
3
2
1
0
RFL.7 RFL.6 RFL.5 RFL.4 RFL.3 RFL.2 RFL.1 RFL.0  
4.10.12 Receive Control Byte Register (RCB)  
Table 42 presents the Receive Control Byte Register, which contains the control field of the frame  
received and stored in internal RAM. RCB is only readable by the CPU and the CPU should  
access RCB only when the SIU is not receiving a frame, RBE = 0. RCB is loaded by the SIU.  
RCB is byte addressable.  
®
IA211010112-04  
UNCONTROLLED WHEN PRINTED OR COPIED  
http://www.Innovasic.com  
Customer Support:  
Page 41 of 65  
1-888-824-4184  
 
 
 
 
 
 
 
 