欢迎访问ic37.com |
会员登录 免费注册
发布采购

TP8044AH-R0117 参数 Datasheet PDF下载

TP8044AH-R0117图片预览
型号: TP8044AH-R0117
PDF下载: 下载PDF文件 查看货源
内容描述: SDLC通信控制器 [SDLC Communications Controller]
分类和应用: 通信控制器
文件页数/大小: 65 页 / 597 K
品牌: INNOVASIC [ INNOVASIC, INC ]
 浏览型号TP8044AH-R0117的Datasheet PDF文件第41页浏览型号TP8044AH-R0117的Datasheet PDF文件第42页浏览型号TP8044AH-R0117的Datasheet PDF文件第43页浏览型号TP8044AH-R0117的Datasheet PDF文件第44页浏览型号TP8044AH-R0117的Datasheet PDF文件第46页浏览型号TP8044AH-R0117的Datasheet PDF文件第47页浏览型号TP8044AH-R0117的Datasheet PDF文件第48页浏览型号TP8044AH-R0117的Datasheet PDF文件第49页  
IA8044/IA8344  
Data Sheet  
SDLC Communications Controller  
March 30, 2010  
The no-control field format is only supported by the FLEXIBLE mode. In this format, TCB and  
RCB are not used and the information field starts immediately after the address field. A control  
field may still be used in the frame but the SIU will treat it as a byte of the information field.  
The no-control field and no-address field formats are supported only by the FLEXIBLE mode. In  
this format STAD, TCB, and RCB are not used and the information field starts immediately after  
the opening flag. This option can only be used with the no-control field option. A control field  
and address field may still be used in the frame but the SIU will treat each as a byte of the  
information field.  
The no FCS field format prevents an FCS from being generated during transmission or being  
checked during reception. This option may be used in conjunction with the other frame format  
options. This option will work with both FLEXIBLE and AUTO modes. In AUTO mode, it  
could cause protocol violations. An FCS field may still be used in the frame but the SIU will treat  
it as a byte of the information field.  
All the possible Frame Format combinations are presented in Table 47, along with the bit settings  
that select a given format.  
Table 47. Frame Format Options  
Frame Option NFCS NB AM  
Frame Format  
Inf  
Standard  
SDLC  
0
0
0
Fl  
Ad  
Co  
FCS  
Fl  
Fl  
FLEXIBLE  
Mode  
Standard  
SDLC  
AUTO Mode  
No-Control  
Field  
0
0
0
1
1
1
Fl  
Fl  
Ad  
Ad  
Co  
Inf  
Inf  
FCS  
Fl  
FCS  
FLEXIBLE  
Mode  
No-Control  
Field  
0
1
0
Fl  
Inf  
FCS  
Fl  
No-Address  
Field  
FLEXIBLE  
Mode  
No-FCS Field  
FLEXIBLE  
Mode  
No-FCS Field  
AUTO Mode  
1
1
0
0
0
1
Fl  
Fl  
Ad  
Ad  
Co  
Co  
Inf  
Inf  
Fl  
Fl  
®
IA211010112-04  
UNCONTROLLED WHEN PRINTED OR COPIED  
http://www.Innovasic.com  
Customer Support:  
Page 45 of 65  
1-888-824-4184  
 
 复制成功!