TLE 6244X
3.6.6 On /off Delay
Times
„On“
B
B
B
C
C
tdon
tson
tdoff
tsoff
∆td
10
5
µs
µs
µs
µs
µs
„Off“
10
10
5
( M e a s u r e m e n t w i t h o h m i c l o a d )
|tdon - tdoff
|
switch-on slew rate
switch-off slew rate
C
C
son
soff
20
25
V/µs
V/µs
3.6.7 Leakage Cur-
rent
U
VDD = 0V, UOUT9...14 = 14V
A
IOUTi
50
µA
(leakage current of the DMOS,
diagnostic current = 0)
U
VDD = 0V, UOUT9...14 = 24V
A
IOUTi
200
µA
(leakage current of the DMOS,
diagnostic current = 0)
3.6.8 Clamping
3.6.8.1 Clamping
Voltage
IOUTi = 0.2A
A
U9...14
40
45
50
V
3.6.8.2 Maximum
Clamping En-
ergy
Linear decreasing current,
max = 30Hz (see diagrams
E = f(I) on page 66)
f
TC ≤ 110°C
I
OUT9...14 ≤ 2.2A
OUT9...14 ≤ 1.0A
C
C
E
E
14
30
mJ
mJ
I
3.6.8.3 Maximum
Clamping En-
ergy
Linear decreasing current,
f
max = 30Hz
TC ≤ 60°C
I
OUT9...14 ≤ 2.2A
OUT9...14 ≤ 1.0A
C
C
C
E
E
17
36
mJ
mJ
I
3.6.8.4 Maximum
Each output 75% of the values of
Clamping En- 3.6.8.2 resp. 3.6.8.3.
ergy with two
Outputs con-
nected in par-
allel
3.6.8.5 Maximum
For a maximum of 10 times during
C
E
E
50
mJ
Clamping En- ECU life (load dump with 400ms
ergy at Load and Ri = 2Ω over the load, e.g. 2W
Dump
lamp)
3.6.8.6 Jump Start
Each output 150% of the values of
3.6.8.3.
C
C
For a maximum of 10 jump starts
of 2 minutes each during ECU life.
3.6.8.7Singlepulse
I
OUT9...14 ≤ 0.6A, max 10 000
50
mJ
TC ≤ 60°C
pulse
Final Data Sheet
51