TLE 6244X
3. Electrical Characteristics
3.1 Operating
Range
Out of this range the power stages
can be shut off by the VDD-moni-
toring except OUT8
(see also 3.13
VDD-monitoring
ABE)
Voltage referred to GND_ABE
UVDD
tRST,min
4.7
15
5.3
V
Minimum reset duration
(Power-On)
ms
Minimum reset duration
in operation mode
tRST,min
1
µs
4.5V ≤ UVDD ≤ 5.5V
3.2 Validity of
Parameters are valid for
4.5V ≤ UVDD ≤ 5.5V,
Parameters
4.5V ≤ UUBatt ≤ 37V
TLE6244: -40°C ≤ TJ ≤ 150°C and
2 power stages in
current limitation
unless otherwise noted.
If VDD-monitoring is active the
power stages are switched off
except OUT8 (see page 28).
Positive current flows into the pin,
negative current flows out of the
pin.
Unless otherwise noted all volt-
ages are referred to GND
(GND1...8 connected with each
other).
If the U
falls below this
VDD
trashed the power stages (except
OUT8) are switched off.
U
U
3.5
4.5
4.2
4.5
V
VDD
VDD
If U
rises above this threshold
VDD
the power stages work regularly
after a delay time of 250 µsec.
Threshold for shut off of OUT8:
If U
rises above this threshold
3.5
5.5
V
V
VDD
the power stages work regularly
after a delay time of 250 µsec.
Supply voltage
UVDD
Final Data Sheet
44
V4.2, 2003-08-29