TLE 6244X
1.6.3 Configuration
The µsec-bus is enabled by this register. In addition the shut off at SCB can be configured for the
power-stages OUT9, OUT10 and OUT15... OUT18.
CONFIG (Read and write)
7
6
5
4
3
2
1
0
1
O16-SCB
O15-SCB
O10-SCB
O9-SCB
O18-SCB
O17-SCB
BMUX
State of Reset: FFh
Bit
0
Name
Description
No function: HIGH on reading
1
BMUX
1: parallel inputs INx enabled
0: µsec-Bus Interface enabled
2
3
4
5
6
7
O17-SCB
O18-SCB
O9-SCB
O10-SCB
O15-SCB
O16-SCB
1: The output OUT17 is switched off in case of SCB
0: The output is not switched off in case of SCB
1: The output OUT18 is switched off in case of SCB
0: The output is not switched off in case of SCB
1: The output OUT9 is switched off in case of SCB
0: The output is not switched off in case of SCB
1: The output OUT10 is switched off in case of SCB
0: The output is not switched off in case of SCB
1: The output OUT15 is switched off in case of SCB
0: The output is not switched off in case of SCB
1: The output OUT16 s switched off in case of SCB
0: The output is not switched off in case of SCB
Description of the µsec-bus see chapter 1.7
Final Data Sheet
20
V4.2, 2003-08-29