Electrical Parameters  
8) ADC module capability.  
9) Not subject to production test, verified by design / characterization.  
10) Value under typical application conditions due to integration (switching noise, etc.).  
11) The sum of DNL/INL/Gain/Offset errors does not exceed the related TUE total unadjusted error.  
12) For 10-bit conversions the DNL/INL/Gain/Offset error values must be multiplied with factor 0.25.  
For 8-bit conversions the DNL/INL/Gain/Offset error values must be multiplied with 0.0625.  
13) The leakage current definition is a continuous function, as shown in Figure 24. The numerical values defined  
determine the characteristic points of the given continuous linear approximation - they do not define step  
function.  
14) Only one of these parameters is tested, the other is verified by design characterization.  
15) IAREF_MAX is valid for the minimum specified conversion time. The current flowing during an ADC conversion  
with a duration of up to tC = 25µs can be calculated with the formula IAREF_MAX = QCONV/tC. Every conversion  
needs a total charge of QCONV = 150pC from VAREF  
.
All ADC conversions with a duration longer than tC = 25µs consume an IAREF_MAX = 6µA.  
16) For the definition of the parameters see also Figure 23.  
17) Applies to AIN0 and AIN1, when used as auxiliary reference inputs.  
18) This represents an equivalent switched capacitance. This capacitance is not switched to the reference voltage  
at once. Instead of this smaller capacitances are successively switched to the reference voltage.  
19) The sampling capacity of the conversion C-Network is pre-charged to VAREF/2 before the sampling moment.  
Because of the parasitic elements the voltage measured at AINx is lower then VAREF/2, typically 0.85V.  