PEB 2091  
PEF 2091  
Operational Description  
Deactivated (Full Reset)  
In the "Deactivated" state the device may enter the low power consumption condition.  
The power-down mode is entered if no monitor messages are active or pending. In  
power-down the Receiver and parts of the interface are deactivated while functions  
related to the IOM®-2-interface and the wake-up detector are still active.  
No signal is sent on the U-interface, the differential outputs AOUT and BOUT are set to  
0 V. The IEC-Q waits for a wake-up signal TN from the NT side or an activation request  
(AR, ARX, AR0, UAR or ARL) from the LT side to start an activation procedure.  
For the recognition of the wake-up signal TN the following procedure applies:  
– TN detected for 4 periods –> transfer within the "Deactivated" state into power-up  
– In power-up both differential outputs are set to 3.2 V  
– TN detected for a total of 12 consecutive periods –> transition criterion TN fulfilled,  
change to next state, if in addition the C/I-command DC is issued in the downstream  
direction.  
– TN detected for more than 4 but less than 12 periods –> return to power-down  
The input sensitivity stated "Analog Characteristics", page 266, presents the minimum  
level required to meet the TN transition criterion. The power-up condition may thus  
already be entered at a lower level.  
Note 43: Refer also to Note 42, page 153, for more information about device  
behavior when a wake-up tone TN is detected in the deactivated state.  
EC Converged  
Upon the EC-coefficients having converged, the IEC-Q starts the transmission of signal  
SL2 and waits for the receipt of signal SN2 from the NT (SEC). If this condition is not met  
within T6, the start-up procedure will be continued. In the case of an analog loop-back,  
this state is left immediately because the EC compensates for the looped back transmit  
signal.  
EC-Training  
The signal SL1 is transmitted on the U-interface to allow the LT Receiver to update its  
EC-coefficients. The "EC-training" state is left when the EC has converged (LSEC) or  
when timer T5 has elapsed. Timer T5 allows the start-up procedure to proceed even if  
LSEC could not be detected, e.g. due to a high noise level on the U-interface.  
EQ-Training  
The "EQ-Training" is left after the Receiver has achieved synchronization and the  
superframe indication has been detected (SFD). Upon expiry of timer T1 the C/I-channel  
indication EI3 is issued.  
Semiconductor Group  