欢迎访问ic37.com |
会员登录 免费注册
发布采购

PEB2091NV5.3 参数 Datasheet PDF下载

PEB2091NV5.3图片预览
型号: PEB2091NV5.3
PDF下载: 下载PDF文件 查看货源
内容描述: 集成电路通信( ISDN Echocancellation电路) [ICs for Communications(ISDN Echocancellation Circuit)]
分类和应用: 电信集成电路综合业务数字网通信
文件页数/大小: 299 页 / 1531 K
品牌: INFINEON [ Infineon ]
 浏览型号PEB2091NV5.3的Datasheet PDF文件第142页浏览型号PEB2091NV5.3的Datasheet PDF文件第143页浏览型号PEB2091NV5.3的Datasheet PDF文件第144页浏览型号PEB2091NV5.3的Datasheet PDF文件第145页浏览型号PEB2091NV5.3的Datasheet PDF文件第147页浏览型号PEB2091NV5.3的Datasheet PDF文件第148页浏览型号PEB2091NV5.3的Datasheet PDF文件第149页浏览型号PEB2091NV5.3的Datasheet PDF文件第150页  
PEB 2091  
PEF 2091  
Operational Description  
– Leave for state "Awake" after NT wake up tone (TN) was detected and the C/I-code  
DC is present in the downstream direction  
– Leave for state "Alerting" after C/I-commands "AR", "ARX", "AR0" or "UAR" and not  
TN were received  
– Leave for state "Reset for Loop" after C/I-command "ARL" was received  
Combinations of transition criteria are possible. Logical "AND" is indicated by "&" (TN &  
DC), logical "OR" is written "or" and for a negation "/" is used. The start of a timer is  
indicated with "TxS" ("x" being equivalent to the timer number). Timers are always  
started when entering the new state. The action resulting after a timer has expired is  
indicated by the path labelled "TxE".  
The sections following the state diagram contain detailed information about all states and  
signals used. These details are mode dependent and may differ for identically named  
signals/states. They are therefore listed for each mode.  
Cold and Warm Starts  
Two types of start-up procedures are supported by the IEC-Q: cold starts and warm  
starts.  
Cold starts are performed after a reset and require all echo and equalizer coefficients to  
be recalculated. This procedure typically is completed after 1-7 seconds depending on  
the line characteristics. Cold starts are recommended for activations where the line  
characteristics have changed considerably since the last deactivation.  
A warm start procedure uses the coefficient set saved during the last deactivation. It is  
therefore completed much faster (maximum 300 ms). Warm starts are however  
restricted to activations where the line characteristics do not change significantly  
between two activations.  
Regarding the path in the transition diagram, cold starts have in particular that the IEC-Q  
has entered the state ’Test’ (e.g. due to a reset) prior to an activation. The activation  
procedure itself is then identical in both cases. Therefore, the following sections apply to  
both warm and cold starts.  
4.4.2  
State Machine in LT Modes  
This section is applicable for the following LT modes:  
– LT mode  
– COT 512 mode  
– COT 1536 mode  
(512 kHz – 4096 kHz)  
(512 kHz)  
(1536 kHz)  
Semiconductor Group  
146  
Data Sheet 01.99  
 
 复制成功!