PEB 2091
PEF 2091
Operational Description
Verification Control for M4 Bits
Table 26 gives the available settings for M4 Bits filtering via MON-8 command.
Table 26
Setting Filtering Method for M4 Bits
Code
Symbol
Function
D7-D0 (Bin)1)
1000 1110
TLL
A change in at least one of the M4 Bits will be passed via
MON-2 only after valid triple last look.
(Default, This is the default setting after reset in all non repeater
not RP) modes
1000 1101
CRC
A change in at least one of the M4 Bits will be passed via
MON-2 only if the CRC is valid for the last two superframes,
(Default, not including the current one.
RP)
This is the default setting after reset in the repeater modes
1000 1111
1000 1100
TLL,
CRC
A change in at least one of the M4 Bits will be passed via
MON-2 only after valid triple last look, and if the CRC is valid
for the last two superframes, not including the current one
On
Every change in at least one of the M4 Bits will be passed
Change via MON-2
1) see Table 25 for definition
Semiconductor Group
122