F3 PWM controller  
ICE3BS03LJG  
Functional Description  
failure such as short winding or short diode, C10 is no generated which prevents the system to enter Auto  
longer able to limit the CS signal at 1.06V. Instead the Restart Mode due to large load jumps.  
comparator C11 detects the peak current voltage >  
1.66V and enters the Latched Off Mode immediately in  
order to keep the SMPS in a safe stage.  
In case of VCC undervoltage, the IC enters into the  
Auto Restart Mode and starts a new startup cycle.  
Short Optocoupler also leads to VCC undervoltage as  
there is no self supply after activating the internal  
reference and bias.  
In contrast to the Latched Off Mode, there is always a  
Startup Phase with switching cycles in Auto Restart  
Mode. After this Start Up Phase, the conditions are  
again checked whether the failure mode is still present.  
Normal operation is resumed once the failure mode is  
removed that had caused the Auto Restart Mode.  
In case the pre-defined Latch Off features are not  
sufficient, there is a customer defined external Latch  
Enable feature. The Latch Off Mode can be triggered  
by pulling down the BL pin to < 0.25V. It can simply add  
a trigger signal to the base of the externally added  
transistor, TLE at the BL pin. To ensure this latch  
function will not be mis-triggered during start up, a 1ms  
delay time is implemented to blank the unstable signal.  
3.7.3.2  
Auto Restart Mode  
BL  
5.0V  
CBK  
#
IBK  
0.9V  
1
S1  
G2  
C3  
C4  
Spike  
Blanking  
30us  
4.0V  
&
20ms  
Blanking  
Time  
G5  
Auto  
Restart  
Mode  
4.0V  
FB  
Control Unit  
Figure 27  
Auto Restart Mode  
In case of Overload or Open Loop, the FB exceeds  
4.0V which will be observed by comparator C4. Then  
the internal blanking counter starts to count. When it  
reaches 20ms, the switch S1 is released. Then the  
clamped voltage 0.9V at VBL can increase. When there  
is no external capacitor CBK connected, the VBL will  
reach 4.0V immediately. When both the input signals at  
AND gate G5 is positive, the Auto-Restart Mode will be  
activated after the extra spike blanking time of 30us is  
elapsed. However, when an extra blanking time is  
needed, it can be achieved by adding an external  
capacitor, CBK. A constant current source of IBK will start  
to charge the capacitor CBK from 0.9V to 4.0V after the  
switch S1 is released. The charging time from 0.9V to  
4.0V are the extendable blanking time. If CBK is 0.22uF  
and IBK is 13uA, the extendable blanking time is around  
52ms and the total blanking time is 72ms. In combining  
the FB and blanking time, there is a blanking window  
Version 2.0  
17  
6 Dec 2007  