F3 PWM controller  
ICE3BS03LJG  
Electrical Characteristics  
4.3.5  
Control Unit  
Parameter  
Symbol  
Limit Values  
Unit  
Test Condition  
min.  
typ.  
max.  
Clamped VBL voltage during  
Normal Operating Mode  
VBLclmp  
VBKC3  
0.85  
0.90  
0.95  
4.15  
4.15  
1.34  
3.65  
3.12  
26.5  
0.33  
16.9  
V
V
V
V
V
V
V
V
µA  
VFB = 4V  
Blanking time voltage limit for  
Comparator C3  
3.85  
3.85  
1.12  
3.35  
2.88  
24.5  
0.17  
9.1  
4.00  
4.00  
1.23  
3.50  
3.00  
25.5  
0.25  
13.0  
Over Load & Open Loop Detection VFBC4  
Limit for Comparator C4  
Active Burst Mode Level for  
Comparator C5  
VFBC5  
VFBC6a  
VFBC6b  
VVCCOVP  
VLE  
Active Burst Mode Level for  
Comparator C6a  
After Active Burst  
Mode is entered  
Active Burst Mode Level for  
Comparator C6b  
After Active Burst  
Mode is entered  
Overvoltage Detection Limit  
Latch Enable level at BL pin  
Charging current at BL pin  
> 30µs  
IBK  
Charge starts after the  
built-in 20ms blanking  
time elapsed  
Latched Thermal Shutdown1)  
TjSD  
tBK  
130  
-
140  
20  
150  
-
°C  
Built-in Blanking Time for  
Overload Protection or enter  
Active Burst Mode  
ms  
without external  
capacitor at BL pin  
Inhibit Time for Latch Enable  
function during Start up  
tIHLE  
-
1.0  
30  
-
ms  
µs  
V
After IC turns on  
Spike Blanking Time before Latch off tSpike  
-
-
or Auto Restart Protection  
Power Down Reset for  
Latched Mode  
VVCCPD  
5.2  
6.23  
7.8  
After Latched Off Mode  
is entered  
1)  
The parameter is not subjected to production test - verified by design/characterization. The thermal shut down  
temperature refers to the junction temperature of the controller.  
Note: The trend of all the voltage levels in the Control Unit is the same regarding the deviation except VVCCOVP  
and VVCCPD  