Technische Information / technical information
IGBT-Module
IGBT-modules
FF600R12IP4
Vorläufige Daten
preliminary data
Schaltverluste Diode-Wechselr. (typisch)
switching losses diode-inverter (typical)
EØþÊ = f (IŒ)
Schaltverluste Diode-Wechselr. (typisch)
switching losses diode-inverter (typical)
EØþÊ = f (R•)
R•ÓÒ = 2.2 Â, V†Š = 600 V
IŒ = 600 A, V†Š = 600 V
80
80
EØþÊ, TÝÎ = 125°C
EØþÊ, TÝÎ = 150°C
EØþÊ, TÝÎ = 125°C
EØþÊ, TÝÎ = 150°C
70
70
60
50
40
30
20
60
50
40
30
20
10
0
0
150 300 450 600 750 900 1050 1200
IŒ [A]
1,0
2,0
3,0
4,0
R• [Â]
5,0
6,0
Transienter Wärmewiderstand Diode-Wechselr.
transient thermal impedance diode-inverter
ZÚÌœ† = f (t)
NTC-Temperaturkennlinie (typisch)
NTC-temperature characteristic (typical)
R = f (T)
100
100000
ZÚÌœ† : Diode
RÚáÔ
10
10000
1000
100
1
i:
rÍ[K/kW]: 6,4
1
2
3
17,8 49,6 1,2
4
τÍ[s]:
0,0008 0,013 0,05 0,6
0,1
0,001
0,01
0,1
t [s]
1
10
0
20
40
60
80
T† [°C]
100 120 140 160
prepared by: AC
approved by: MS
date of publication: 2009-08-13
revision: 2.4
7