Data sheet BTS 6163 D
Parameter and Conditions
Symbol
Values
Unit
at T= 25, V = 24 V unless otherwise specified
bb
j
min
typ
max
Protection Functions 12)
Short circuit current limit (Tab to pin 1,5) 13)
14)
Short circuit current limit at VON = 6V
Short circuit current limit at VON = 12V
Short circuit current limit at VON = 18V
Tj =-40°C: IL6(SC)
--
--
90
80
65
110
--
A
A
A
A
A
A
Tj =25°C:
Tj =+150°C:
50
--
14)
14)
Tj =-40°C: IL12(SC)
Tj =25°C:
Tj =+150°C:
Tj =-40°C: IL18(SC)
Tj =25°C:
Tj =+150°C:
Tj =-40°C: IL24(SC)
Tj =25°C:
Tj =+150°C:
Tj =-40°C: IL30(SC)
Tj =25°C:
Tj =+150°C:
--
--
40
80
70
55
100
--
--
--
--
30
55
50
48
80
--
--
Short circuit current limit at VON = 24V
--
--
25
45
40
35
60
--
--
tm=170µs
Short circuit current limit at VON = 30V
--
--
20
30
30
30
50
--
--
tm=170µs
14)
Short circuit current limit at VON = 45V
Tj =-40°C: IL45(SC)
Tj =25°C:
Tj =+150°C:
--
--
15
22
22
22
35
--
--
Short circuit shutdown detection voltage
(pin 3 to pins 1,5)
VON(SC)
td(SC1)
2.5
3.5
4.5
V
Short circuit shutdown delay after input current
positive slope, VON > VON(SC), Tj =-40...+150°C
min. value valid only if input "off-signal" time exceeds 30 µs
350
650 1200
µs
Short circuit shutdown delay during on condition13)
VON > VON(SC)
td(SC2)
--
2
--
--
µs
Output clamp (inductive load switch off) 15)
at VOUT = Vbb - VON(CL) (e.g. overvoltage)
IL= 40 mA
VON(CL)
63
67
V
Thermal overload trip temperature
Thermal hysteresis
Tjt
150
--
175
10
--
--
°C
K
∆Tjt
12)
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
13)
14)
15)
Short circuit current limit for max. duration of t
d(SC1)
, prior to shutdown, see also figures 3.x on page 13.
not subject to production test, specified by design
See also figure 2b on page 12.
Infineon Technologies AG
Page 5 of 16
2003-Oct-01