BTS 5210G  
Parameter and Conditions, each of the four channels Symbol  
Values  
Unit  
at Tj = -40...+150°C, V = 12 V unless otherwise specified  
bb  
min  
typ  
max  
Reverse Battery  
Reverse battery voltage 17)  
-Vbb  
--  
--  
--  
32  
--  
V
Drain-source diode voltage (V > V  
)
-VON  
600  
mV  
out  
bb  
IL =-2.0A, Tj =+150°C  
Diagnostic Characteristics  
Open load detection voltage  
V OUT(OL)  
1.7  
2.5  
2.8  
4.0  
4.0  
6.0  
V
1
Input and Status Feedback18)  
Input resistance  
(see circuit page 9)  
RI  
kΩ  
Input turn-on threshold voltage  
Input turn-off threshold voltage  
Input threshold hysteresis  
Status change after positive input slope19)  
with open load  
VIN(T+)  
VIN(T-)  
--  
1.0  
--  
--  
--  
2.5  
--  
V
V
VIN(T)  
td(STon)  
0.2  
10  
--  
V
--  
20  
µs  
Status change after positive input slope19)  
with overload  
td(STon)  
td(SToff)  
td(SToff)  
30  
--  
--  
--  
--  
--  
500  
20  
µs  
µs  
µs  
Status change after negative input slope  
with open load  
Status change after negative input slope19)  
--  
with overtemperature  
Off state input current  
On state input current  
Status output (open drain)  
Zener limit voltage  
VIN = 0.4 V: IIN(off)  
VIN = 5 V: IIN(on)  
5
--  
20  
60  
µA  
µA  
10  
35  
IST = +1.6 mA: VST(high)  
IST = +1.6 mA: VST(low)  
5.4  
--  
--  
--  
--  
0.6  
V
ST low voltage  
17)  
Requires a 150 resistor in GND connection. The reverse load current through the intrinsic drain-source  
diode has to be limited by the connected load. Power dissipation is higher compared to normal operating  
conditions due to the voltage drop across the drain-source diode. The temperature protection is not active  
during reverse current operation! Input and Status currents have to be limited (see max. ratings page 4 and  
circuit page 9).  
18)  
19)  
If ground resistors R  
are used, add the voltage drop across these resistors.  
GND  
not subject to production test, specified by design  