欢迎访问ic37.com |
会员登录 免费注册
发布采购

BTS3080TF 参数 Datasheet PDF下载

BTS3080TF图片预览
型号: BTS3080TF
PDF下载: 下载PDF文件 查看货源
内容描述: [BTS3080TF 是一款 80 mΩ 智能单通道低边电源开关,采用 PG-T0252-3 封装,提供嵌入式保护功能。功率晶体管由 N 通道垂直功率MOSFET 构成。]
分类和应用: 开关驱动电源开关接口集成电路晶体管
文件页数/大小: 39 页 / 1119 K
品牌: INFINEON [ Infineon ]
 浏览型号BTS3080TF的Datasheet PDF文件第3页浏览型号BTS3080TF的Datasheet PDF文件第4页浏览型号BTS3080TF的Datasheet PDF文件第5页浏览型号BTS3080TF的Datasheet PDF文件第6页浏览型号BTS3080TF的Datasheet PDF文件第8页浏览型号BTS3080TF的Datasheet PDF文件第9页浏览型号BTS3080TF的Datasheet PDF文件第10页浏览型号BTS3080TF的Datasheet PDF文件第11页  
HITFET - BTS3080TF  
Smart Low-Side Power Switch  
General Product Characteristics  
Table 2  
Absolute Maximum Ratings 1) (cont’d)  
Tj = -40°C to +150°C; all voltages with respect to ground, positive current flowing into pin (unless otherwise  
specified)  
Parameter  
Symbol  
Values  
Unit Note or Test Condition Number  
Min. Typ. Max.  
Temperatures  
Operating temperature  
Storage temperature  
ESD Susceptibility  
ESD susceptibility (all pins)  
TJ  
-40  
-55  
+150 °C  
+150 °C  
P_4.1.37  
P_4.1.38  
TSTG  
VESD  
VESD  
-4  
4
kV  
kV  
HBM4)  
HBM4)  
P_4.1.39  
P_4.1.40  
ESD susceptibility OUT-pin to  
GND  
-10  
10  
ESD susceptibility  
VESD  
-2  
2
KV  
CDM5)  
P_4.1.41  
1) Not subject to production test, specified by design.  
2) VBAT(LD) is setup without the DUT connected to the generator per ISO 7637-1;  
RI is the internal resistance of the load dump test pulse generator;  
tD is the pulse duration time for load dump pulse (pulse 5) according ISO 7637-1, -2.  
3) Maximum allowed value. Consider also inverse input current in inverse condition P_8.3.7 in Chapter 8  
4) ESD susceptibility, HBM according to ANSI/ESDA/JEDEC JS001 (1.5 k, 100 pF)  
5) ESD susceptibility, Charged Device Model “CDM” ESDA STM5.3.1 or ANSI/ESD S.5.3.1  
Notes  
1. Stresses above the ones listed here may cause permanent damage to the device. Exposure to absolute  
maximum rating conditions for extended periods may affect device reliability.  
2. Integrated protection functions are designed to prevent IC destruction under fault conditions described in the  
data sheet. Fault conditions are considered as “outside” normal operating range. Protection functions are  
not designed for continuous repetitive operation.  
4.2  
Functional Range  
Table 3  
Functional Range 1)  
Please refer to “Electrical Characteristics” on Page 18 for test conditions  
Parameter  
Symbol  
Values  
Unit Note or Test Condition Number  
Min. Typ. Max.  
Battery Voltage Range for Nominal VBAT(NOR) 6.0  
Operation  
18.0  
V
V
P_4.2.1  
P_4.2.2  
Extended Battery Voltage Range VBAT(EXT)  
0
31  
parameter deviations  
possible  
for Operation  
Input Voltage Range for Nominal VIN(NOR)  
Operation  
3.0  
-40  
5.5  
V
P_4.2.3  
P_4.2.5  
Junction Temperature  
TJ  
150  
°C  
Datasheet  
7
Rev. 1.0  
2016-06-01  
 复制成功!