ICS341
FIELD PROGRAMMABLE SS VERSACLOCK SYNTHESIZER
EPROM CLOCK SYNTHESIZER
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS341. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Parameter
Condition
Min.
-0.5
-0.5
-0.5
-65
Typ.
Max.
7
Units
V
Supply Voltage, VDD
Inputs
Referenced to GND
Referenced to GND
Referenced to GND
VDD+ 0.5
VDD+ 0.5
150
V
Clock Outputs
V
Storage Temperature
Soldering Temperature
Junction Temperature
C
C
C
Max 10 seconds
260
125
Recommended Operation Conditions
Parameter
Min.
0
Typ.
Max.
+70
+85
+3.45
4
Units
C
Ambient Operating Temperature (ICS341M)
Ambient Operating Temperature (ICS341MI)
Power Supply Voltage (measured in respect to GND)
Power Supply Ramp Time
-40
C
+3.15
+3.3
V
ms
IDT® / ICS™ FIELD PROGRAMMABLE SS VERSACLOCK SYNTHESIZER
4
ICS341