欢迎访问ic37.com |
会员登录 免费注册
发布采购

332M-33LF 参数 Datasheet PDF下载

332M-33LF图片预览
型号: 332M-33LF
PDF下载: 下载PDF文件 查看货源
内容描述: [Clock Generator, 120MHz, CMOS, PDSO8, 0.150 INCH, ROHS COMPLIANT, SOIC-8]
分类和应用: 时钟光电二极管外围集成电路晶体
文件页数/大小: 5 页 / 97 K
品牌: IDT [ INTEGRATED DEVICE TECHNOLOGY ]
 浏览型号332M-33LF的Datasheet PDF文件第1页浏览型号332M-33LF的Datasheet PDF文件第2页浏览型号332M-33LF的Datasheet PDF文件第4页浏览型号332M-33LF的Datasheet PDF文件第5页  
ICS332-33
Dual Output Clock Synthesizer
load capacitance, each crystal capacitor would be 20
pF [(16-6) x 2 = 20].
PCB Layout Recommendations
For optimum device performance and lowest output
phase noise, the following guidelines should be
observed.
1) The 0.01µF decoupling capacitor should be mounted
on the component side of the board as close to the
VDD pin as possible. No vias should be used between
decoupling capacitor and VDD pin. The PCB trace to
VDD pin should be kept as short as possible, as should
the PCB trace to the ground via. Distance of the ferrite
bead and bulk decoupling from the device is less
critical.
2) The external crystal should be mounted just next to
the device with short traces. The X1 and X2 traces
should not be routed next to each other with minimum
spaces, instead they should be separated and away
from other traces.
3) To minimize EMI, the 33
series termination resistor
(if needed) should be placed close to the clock output.
4) An optimum layout is one with all components on the
same side of the board, minimizing vias through other
signal layers (the ferrite bead and bulk decoupling
capacitor can be mounted on the back). Other signal
traces should be routed away from the ICS332-33. This
includes signal traces just underneath the device, or on
layers adjacent to the ground plane layer used by the
device.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS332-33. These ratings,
which are standard values for IDT commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage, VDD
All Inputs and Outputs
Ambient Operating Temperature
Storage Temperature
Junction Temperature
Soldering Temperature
7V
Rating
-0.5 V to VDD+0.5 V
0 to +70
°
C
-65 to +150
°
C
125
°
C
260
°
C
Recommended Operation Conditions
Parameter
Ambient Operating Temperature
Power Supply Voltage (measured in respect to GND)
Min.
0
+3.15
Typ.
+3.3
Max.
+70
+3.45
Units
°
C
V
MDS 332-33 D
3
I n t e gra te d D ev i ce Technology, Inc.
Revision 051310
w w w. i d t . c o m