IDT2308B
3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
CLOCK MULTIPLIER
Available Options for IDT2308B
Device
Feedback From
Bank A Frequency
Reference
Bank B Frequency
IDT2308B-1
IDT2308B-1H
IDT2308B-2
IDT2308B-2
IDT2308B-2H
IDT2308B-2H
IDT2308B-3
IDT2308B-3
IDT2308B-4
IDT2308B-5H
Bank A or Bank B
Bank A or Bank B
Bank A
Reference
Reference
Reference
Reference
Reference/2
Bank B
2 x Reference
Reference
Reference
Bank A
Reference/2
Bank B
2 x Reference
2 x Reference
4 x Reference
2 x Reference
Reference/2
Reference
Bank A
Reference or Reference1
2 x Reference
2 x Reference
Reference/2
Bank B
Bank A or Bank B
Bank A or Bank B
Note 1: Output phase is indeterminant (0° or 180° from input clock).
Absolute Maximum Ratings1
Symbol
Rating
Max.
-0.5 V to +4.6
-0.5 V to +5.5
-0.5 to VDD + 0.5
-50
Unit
V
VDD
VI2
VI
Supply Voltage Range
Input Voltage Range (REF)
Input Voltage Range (except REF)
Input Clamp Current
V
V
IIK (VI < 0)
mA
mA
IOK (VO < 0 or VO > VDD)
Terminal Voltage with Respect to
GND (inputs VIH 2.5, VIL 2.5)
50
I
O (VO = 0 to VDD)
Continuous Output Current
50
100
mA
mA
W
VDD or GND
Continuous Current
TA = 55 °C (in still air only)3 Maximum Power Dissipation
0.7
TSTG
Storage Temperature Range
Commercial range
-65 to +150
0 to +70
-40 to +85
°C
°C
°C
Operating Temperature
Operating Temperature
Industrial range
Notes:
1. Stresses above the ratings listed below can cause permanent damage to the IDT2308B. These ratings, which are standard
values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these or any other
conditions above those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods can affect product reliability. Electrical parameters are guaranteed only over
the recommended operating temperature range.
2. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
3. The maximum package power dissipation is calculated using a junction temperature of 150°C and a board trace length of 750
mils.
IDT™ 3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
3
IDT2308B
REV B 030509