IDT2308B
3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
CLOCK MULTIPLIER
Operating Conditions–Industrial
Symbol
VDD
Parameter
Conditions
Min.
Max.
3.6
+85
30
Units
V
Supply Voltage
3
-40
–
TA
Operating Temperature (Ambient Temperature)
Load Capacitance below 100 MHz
Load Capacitance from 100 MHz to 133 MHz
Input Capacitance1
°C
CL
pF
–
15
pF
CIN
–
7
pF
Note 1: Applies to both REF and FBK.
DC Electrical Characteristics–Industrial
Parameter
Input High Voltage Level
Input Low Voltage Level
Input Low Current
Symbol
VIH
Conditions
Min.
Typ. Max. Units
2
V
VIL
0.8
50
V
µA
µA
V
IIL
VIN = 0V
Input High Current
IIH
VIN = VDD
100
Output High Voltage
VOH
IOH = -8 mA (-1, -2, -3, -4)
2.4
IOH = -12 mA (-1H, -2H, -5H)
Output Low Voltage
Power Down Current
VOL
IOL = 8 mA (-1, -2, -3, -4)
IOL = 12 mA (-1H, -2H, -5H)
0.4
V
IDD_PD REF = 0MHz (S2 = S1 = H)
25
45
70
32
50
18
30
µA
100 MHz CLKA (-1, -2, -3, -4)
100 MHz CLKA (-1H, -2H, -5H)
66 MHz CLKA (-1, -2, -3, -4)
66 MHz CLKA (-1H, -2H, -5H)
33 MHz CLKA (-1, -2, -3, -4)
33 MHz CLKA (-1H, -2H, -5H)
Unloaded Outputs
Select Inputs at VDD or
GND
Supply Current
IDD
mA
IDT™ 3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
7
IDT2308B