IDT2308B
3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
CLOCK MULTIPLIER
Operating Conditions–Commercial
Symbol
V
DD
T
A
C
L
C
IN
Supply Voltage
Operating Temperature (Ambient Temperature)
Load Capacitance below 100 MHz
Load Capacitance from 100 MHz to 133 MHz
Input Capacitance
1
Parameter
Conditions
Min.
3
0
–
–
–
Max.
3.6
70
30
15
7
Units
V
°C
pF
pF
pF
Note 1:
Applies to both REF and FBK.
DC Electrical Characteristics–Commercial
Parameter
Input High Voltage Level
Input Low Voltage Level
Input Low Current
Input High Current
Output High Voltage
Output Low Voltage
Power Down Current
Symbol
V
IH
V
IL
I
IL
I
IH
V
OH
V
OL
I
DD_PD
V
IN
= 0V
V
IN
= V
DD
Conditions
Min.
2
Typ.
Max.
0.8
50
100
Units
V
V
µA
µA
V
I
OH
= -8 mA (-1, -2, -3, -4)
I
OH
= -12 mA (-1H, -2H, -5H)
I
OL
= 8 mA (-1, -2, -3, -4)
I
OL
= 12 mA (-1H, -2H, -5H)
REF = 0MHz (S2 = S1 = H)
100 MHz CLKA (-1, -2, -3, -4)
100 MHz CLKA (-1H, -2H, -5H)
Unloaded Outputs
Select Inputs at V
DD
or
GND
66 MHz CLKA (-1, -2, -3, -4)
66 MHz CLKA (-1H, -2H, -5H)
33 MHz CLKA (-1, -2, -3, -4)
33 MHz CLKA (-1H, -2H, -5H)
2.4
0.4
12
45
70
32
50
18
30
V
µA
Supply Current
I
DD
mA
IDT™
3.3 VOLT ZERO DELAY CLOCK MULTIPLIER
5
IDT2308B
REV B 030509