Chapter 8 Management Register Set  
8.3.9 Remote Fault (bit 1.4)  
An STA reads bit 1.4 to determine if a Remote Fault exists. The ICS1893AF sets bit 1.4 based on the  
Remote Fault bit received from its remote link partner. The ICS1893AF receives the Remote Fault bit as  
part of the Link Code Word exchanged during the auto-negotiation process. If the ICS1893AF receives a  
Link Code Word from its remote link partner and the Remote Fault bit is set to:  
Zero, then the ICS1893AF sets bit 1.4 to logic zero.  
One, then the ICS1893AF sets bit 1.4 to logic one. In this case, the remote link partner is reporting the  
detection of a fault, which typically occurs when the remote link partner is having a problem with its  
receive channel.  
Bit 1.4 is a latching high status bit. (For more information on latching high and latching low bits, see Section  
8.1.4.1, “Latching High Bits” and Section 8.1.4.2, “Latching Low Bits”.)  
Note: The ICS1893AF has two versions of the Remote Fault bit.  
One version of the Remote Fault bit is a latching high version. An STA can access this version  
through either Management Register 1 (bit 1.4) or 17 (bit 17.1). This bit 1.4/17.1 is cleared when  
an STA reads either of these registers. (Bit 1.4 is identical to bit 17.1 in that they are the same  
internal bit.)  
Another version of the Remote Fault bit is updated whenever the ICS1893AF receives a new  
Link Control Word. An STA can access this version through Management Register 5 (bit 5.13),  
which like bits 1.4/17.1, also reports the status of the Remote Fault bit received from the remote  
link partner. However, bit 5.13 is not a latching high bit.  
The operation of both bit 1.4/17.1 and bit 5.13 are in compliance with the IEEE Std 802.3u.  
8.3.10 Auto-Negotiation Ability (bit 1.3)  
The STA reads bit 1.3 to determine if the ICS1893AF can support the auto-negotiation process. If the  
ICS1893AF:  
Cannot support the auto-negotiation process, it clears bit 1.3 to logic zero.  
Can support the auto-negotiation process, it sets bit 1.3 to logic one. (For the ICS1893AF, the default  
value of bit 1.3 is logic one.)  
ICS1893AF
Copyright © 2004, Integrated Circuit Systems, Inc.  