ICS1893AF Data Sheet - Release  
Chapter 8 Management Register Set  
8.3.6 IEEE Reserved Bits (bits 1.10:7)  
The IEEE reserves these bits for future use. When an STA:  
Reads a reserved bit, the ICS1893AF returns a logic zero.  
Writes a reserved bit, the STA must use the default value specified in this data sheet.  
Both the ISO/IEC standard and the ICS1893AF reserve the use of some Management Register bits. ICS  
uses some reserved bits to invoke ICS1893AF test functions. To ensure proper operation of the  
ICS1893AF, an STA must maintain the default value of these bits. Therefore, ICS recommends that an STA  
write the default value to all reserved bits during all Management Register write operations.  
Reserved bits 1.10:7 are Command Override Write (CW) bits. When bit 16.15, the Command Register  
Override bit, is logic:  
Zero, the ICS1893AF prevents all STA writes to CW bits.  
One, an STA can modify the value of these bits.  
8.3.7 MF Preamble Suppression (bit 1.6)  
Status Register bit 1.6 is the Management Frame (MF) Preamble Suppression bit. The ICS1893AF sets bit  
1.6 to inform the STA of its ability to receive frames that do not have a preamble. When this bit is logic:  
Zero, the ICS1893AF is indicating it cannot accept frames with a suppressed preamble.  
One, the ICS1893AF is indicating it can accept frames that do not have a preamble.  
Although the ICS1893AF supports Management Frame Preamble Suppression, its default value for bit 1.6  
is logic zero. This default value ensures that bit 1.6 is backward compatible with the ICS1890, which does  
not have this capability. As the means of enabling this feature, the ICS1893AF implements bit 1.6 as a  
Command Override Write bit, instead of as a Read-Only bit as in the ICS1890. An STA uses the bit 1.6 to  
enable MF Preamble Suppression in the ICS1893AF. [See the description of bit 16.15, the Command  
Override Write Enable bit, in Section 8.11, “Register 16: Extended Control Register”.]  
8.3.8 Auto-Negotiation Complete (bit 1.5)  
An STA reads bit 1.5 to determine the state of the ICS1893AF auto-negotiation process. The ICS1893AF  
sets the value of this bit using two criteria. When its Auto-Negotiation sublayer is:  
Disabled, the ICS1893AF sets bit 1.5 to logic zero.  
Enabled, the ICS1893AF sets bit 1.5 to a value based on the state of the Auto-Negotiation State  
Machine. In this case, it sets bit 1.5 to logic one only upon completion of the auto-negotiation process.  
This setting indicates to the STA that a link is arbitrated and the contents of Management Registers 4, 5,  
and 6 are valid. For details on the auto-negotiation process, see Section 7.2, “Functional Block:  
Auto-Negotiation”.  
Bit 1.5 is a latching high (LH) bit. (For more information on latching high and latching low bits, see Section  
8.1.4.1, “Latching High Bits” and Section 8.1.4.2, “Latching Low Bits”.)  
Note: An Auto-Negotiation Restart does not clear an LH bit. However, performing two consecutive reads  
of this register provides the present state of the bit.  
ICS1893AF,