ICS1892
10Base-T/100Base-TX Integrated PHYceiver™
TSD
Chapter 10 DC and AC Operating Conditions
ICS1892 Data Sheet
Chapter 10 DC and AC Operating Conditions
10.1 Absolute Maximum Ratings
Table 10-1 lists the absolute maximum ratings for the ICS1892. Stresses above these ratings can cause
permanent damage to the ICS1892. These ratings, which are standard values for ICS commercially rated
parts, are stress ratings only. Functional operation of the ICS1892 at these or any other conditions above
those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods can affect product reliability. Electrical parameters are
guaranteed only over the recommended operating temperature range.
Table 10-1. Absolute Maximum Ratings
Item
Rating
V
DD (measured to VSS
)
5.5 V
Digital Inputs / Outputs
Storage Temperature
Junction Temperature
Soldering Temperature
Power Dissipation
V
SS -0.5 to VDD +0.5 V
-65 to +150° C
125° C
260° C
See Section 10.4.1, “DC Operating Characteristics for Supply Current”
10.2 Recommended Operating Conditions
Table 10-2 lists the recommended operating conditions for the ICS1892.
Table 10-2. Recommended Operating Conditions
Parameter
Symbol Conditions Minimum Maximum
Units
° C
V
Ambient Operating Temperature
TA
–
–
0
+70
Power Supply Voltage
VDD
+4.75
+5.25
(measured with respect to VSS
)
ICS1892, Rev. D, 2/26/01
February 26, 2001
© 2000-2001, Integrated Circuit Systems, Inc.
All rights reserved.
120
IDT™ / ICS™ 10Base-T/100Base-TX Integrated PHYceiver™
ICS1892
120