ICS1893CF Data Sheet - Release  
Chapter 6 Functional Blocks  
6.2.3 Auto-Negotiation: Remote Fault Signaling  
If the remote link partner detects a fault, the ICS1893CF reports the remotely detected fault to the STA by  
setting to logic one the Remote Fault Detected bit(s), 1.4, 5.13, 17.1, and 19.13. In general, the reception  
of a remote fault means that the remote link partner has a problem with the integrity of its receive channel.  
Similarly, if the ICS1893CF detects a link fault, it transmits a remote fault-detected condition to its remote  
link partner. In this situation, the ICS1893CF sets to logic one the Auto-Negotiation Link Partner Ability  
Register’s Remote Fault Indication bit (bit 4.13).  
For details, see Section 7.14.3, “Remote Fault (bit 19.13)” and Section 7.3.9, “Remote Fault (bit 1.4)”.  
6.2.4 Auto-Negotiation: Reset and Restart  
If enabled, execution of the ICS1893CF auto-negotiation process occurs at power-up and upon  
management request. There are two primary ways to begin the Auto-Negotiation state machine:  
ICS1893CF reset  
Auto-Negotiation Restart  
6.2.4.1 Auto-Negotiation Reset  
During a reset, the ICS1893CF initializes its Auto-Negotiation sublayer modules to their default states.  
(That is, the Auto-Negotiation Arbitration State Machine and the Auto-Negotiation Progress Monitor reset to  
their idle states.) In addition, the Auto-Negotiation Progress Monitor status bits are all set to logic zero. This  
action occurs for any type of reset (hardware reset, software reset, or power-on reset).  
6.2.4.2 Auto-Negotiation Restart  
As with a reset, during an Auto-Negotiation restart, the ICS1893CF initializes the Auto-Negotiation  
Arbitration State Machine and the Auto-Negotiation Progress Monitor modules to their default states.  
However, during an Auto-Negotiation Restart, the Auto-Negotiation Progress Monitor status bits maintain  
their current state. Only three events can alter the state of the Auto-Negotiation Progress Monitor status  
bits after a Restart: (1) an STA read operation, (2) a reset, or (3) the Auto-Negotiation Arbitration State  
Machine progressing to a higher state or value.  
The Auto-Negotiation Progress Monitor Status bits change only if they are progressing to a state with a  
value greater than their current state (that is, a state with a higher logical value than that of their current  
state). For a detailed explanation of these bits and their operation, see Section 6.2.5, “Auto-Negotiation:  
Progress Monitor”.  
After the Auto-Negotiation Arbitration State Machine reaches its final state (which is Auto-Negotiation  
Complete), only an STA read of the QuickPoll Detailed Status Register or an ICS1893CF reset can alter  
these status bits.  
Any of the following situations initiates a restart of the ICS1893CF Auto-Negotiation sublayer:  
A link failure  
In software mode:  
– Writing a logic one to the Control Register’s Restart Auto-Negotiation bit (bit 0.9), which is a self-  
clearing bit.  
Toggling the Control Register’s Auto-Negotiation Enable bit (bit 0.12) from a logic one to a logic zero,  
and back to a logic one.  