ICS1893CF Data Sheet Rev. F - Release  
Chapter 6 Functional Blocks  
6.1 Functional Block: Media Independent Interface  
All ICS1893CF MII interface signals are fully compliant with the ISO/IEC 8802-3 standard. In addition, the  
ICS1893CF MIIs can support two data transfer rates: 25 MHz (for 100Base-TX operations) and 2.5 MHz  
(for 10Base-T operations).  
The Media Independent Interface (MII) consists of two primary components:  
1. An interface between a MAC (Media Access Control sublayer) and the PHY (that is, the ICS1893CF).  
This MAC-PHY part of the MII consists of three subcomponents:  
a. A synchronous Transmit interface that includes the following signals:  
(1) A data nibble, TXD[3:0]  
(2) A delimiter, TXEN  
(3) A clock, TXCLK  
b. A synchronous Receive interface that includes the followings signals:  
(1) A data nibble, RXD[3:0]  
(2) An error indicator, RXER  
(3) A delimiter, RXDV  
(4) A clock, RXCLK  
c. A Media Status or Control interface that consists of a Carrier Sense signal (CRS) and a Collision  
Detection signal (COL).  
2. An interface between the PHY (the ICS1893CF) and an STA (Station Management entity). The  
STA-PHY part of the MII is a two-wire, Serial Management Interface that consists of the following:  
a. A clock (MDC)  
b. A synchronous, bi-directional data signal (MDIO) that provides an STA with access to the  
ICS1893CF Management Register set  
The ICS1893CF Management Register set (discussed in Chapter 7, “Management Register Set”) consists  
of the following:  
Basic Management registers.  
As defined in the ISO/IEC 8802-3 standard, these registers include the following:  
– Control Register (register 0), which handles basic device configuration  
– Status Register (register 1), which reports basic device capabilities and status  
Extended Management registers.  
As defined in the ISO/IEC 8802-3 standard, the ICS1893CF supports Extended registers that provide  
access to the Organizationally Unique Identifier and all auto-negotiation functionality.  
ICS (Vendor-Specific) Management registers.  
The ICS1893CF provides vendor-specific registers for enhanced PHY operations. Among these is the  
QuickPoll Detailed Status Register that provides a comprehensive and consolidated set of real-time PHY  
information. Reading the QuickPoll register enables the MAC to obtain comprehensive status data with a  
single register access.  