iC-NQ  
13-bit Sin/D CONVERTER WITH CALIBRATION  
Rev D1, Page 17/25  
SIGNAL MONITORING and ERROR MESSAGES  
Vss  
SELAMPL Adr 0x0C, Bit 2  
Vth  
AMPL  
Adr 0x0C, Bit 1:0  
Max ( |Sin| , |Cos| )  
Voltage threshold Vth  
0.60 x VDDA  
Code  
0x00  
0x01  
0x02  
0x03  
Output amplitude*  
1.4 Vpp (0.28 x VDDA)  
2.0 Vpp (0.40 x VDDA)  
2.6 Vpp (0.51 x VDDA)  
3.1 Vpp (0.62 x VDDA)  
0.64 x VDDA  
0.68 x VDDA  
0.72 x VDDA  
Sin2 + Cos2  
Figure 15: Signal monitoring of minimum amplitude.  
Code  
0x04  
0x05  
0x06  
0x07  
Notes  
Vthmin Vthmax  
Output amplitude*  
2.4 Vpp 3.4 Vpp  
2.8 Vpp 3.8 Vpp  
3.2 Vpp 4.2 Vpp  
3.6 Vpp 4.6 Vpp  
Vthmax  
Vthmin  
0.48 0.68 x VDDA  
0.56 0.76 x VDDA  
0.64 0.84 x VDDA  
0.72 0.92 x VDDA  
*) Entries are calculated with VDDA = 5 V.  
Table 24: Signal Amplitude Monitoring  
Figure 16: Sin2 + Cos2 signal monitoring.  
AERR  
Code  
0x00  
Adr 0x03, Bit 1  
Amplitude error message  
disabled  
Each phase in the configuration process is signaled by  
NERR = low; the signal is only reset following a suc-  
cessful CRC (cyclic redundancy check).  
0x01  
enabled  
If the data transfer from the EEPROM is faulty and the  
CRC unsuccessful, then the configuration phase is au-  
tomatically repeated.  
Table 25: Amplitude Error  
FERR  
Code  
0x00  
0x01  
Note  
Adr 0x03, Bit 0  
Excessive frequency error message  
The process aborts following a third unsuccessful at-  
tempt and the error message output remains set to low  
until a write access occurs at address 0 via the BiSS  
Interface (internal reset).  
disabled  
enabled  
Input frequency monitoring is operational for  
resolutions 16  
Table 26: Frequency Error  
To enable the successful diagnosis of faults other types  
of error are signaled at NERR using a PWM code as  
given in the key on the left.  
Configuration Error  
-
Messaging always released  
Two error bits are provided to enable communication  
via the BiSS Interface; these bits can decode four dif-  
ferent types of error. If NERR is held at low by an ex-  
ternal source, such as an error message from the sys-  
tem, for example, this can also be verified via the BiSS  
Interface.  
Table 27: Configuration Error  
Error Keys  
Failure Mode  
Pin NERR  
HI  
Error bits E1, E0 with  
BiSS and SSI  
No error  
11  
Amplitude error  
LO/HI = 75 %  
(AERR = 0: HI)  
01  
(11)  
Error events are stored for the BiSS sensor data output  
and deleted afterwards. Errors at NERR are displayed  
for a minimum of ca. 10 ms, as far as no BiSS readout  
causes a deletion.  
Frequency error  
LO/HI = 50 %  
(FERR = 0: HI)  
10  
(11)  
Configuration  
Undervoltage  
System error  
LO  
LO  
00  
00  
00  
NERR = low caused  
by an external error  
signal  
If an error in amplitude occurs the conversion pro-  
cess is terminated and the incremental output signals  
halted. An error in amplitude rules out the possibility of  
an error in frequency.  
Table 28: Error Keys