iC-ML  
HALL Position Sensor / Encoder  
Rev A3, Page 8/17  
this vector rotates counterclockwise (mathematically  
positive rotation), whereas if the tape is moved in pos-  
itive x-direction (with respect to the chip), the vector  
rotates clockwise (mathematically negative rotation).  
Figure 7: Sensing of a pole wheel at the peripherie  
using iC-ML  
When the Vcos and Vsin signals are displayed as a  
Lissajou figure, a rotating vector is defined. If the chip  
is moved in positive x-direction with respect to the tape,  
Figure 8: Signal outputs Vsin und Vcos  
Programming the configuration  
iC-ML has 28 modes of operation (see tables on the In standby all ports are switched to tristate, i.e. high  
following pages). After the device has been switched impedance. Only in chain operation modes port D is  
on or "woken up" from standby mode by a low sig- active high so that the devices arranged further behind  
nal at pin NEN the levels at the configuration inputs can also be deactivated.  
CFG1 to CFG3 are assessed. These three-level in-  
puts can be connected to GND (low), left open (open)  
or connected to VDD (high). For correct identification,  
4V  
VDD  
a setup time of at least tp(CFGx) = 4 µs must be main-  
tained between programming the configuration and ac-  
NEN  
tivating the device. While the device is active changes  
in signal at the configuration inputs are ignored.  
iC-ML active  
iC-ML active  
CFGx  
If several iC-MLs are connected in series in chain op-  
eration (see the description of functions on page 12)  
it must be ensured that the NEN input of the devices  
is switched to low during the various clock cycles and  
that the programming default does thus not lie within  
the active phase of the devices.  
td(VDD)on  
tp(CFGx)  
tp(CFGx)  
Figure 9: Programming the configuration  
 
 