iC-JRX  
µP INTERFACE WITH 2×4 24V HIGH-SIDE DRIVERS  
Rev A1, Page 10/23  
Interrupt Status Register (read only)  
Add.: 2  
reset entry: 00h  
higher nibble  
lower nibble  
Bit  
7
6
5
4
3
-
2
1
0
Name  
DCHI  
IET2  
IET1  
ISCI  
ET2  
ET1  
SCS  
higher nibble  
overcurrent, excessive temperature, change-of-input data (interrupts stored)  
Read access gates off changes to the register; the register is reenabled only when reset via EOI. Any  
successive interrupts for IET1 and IET2 which occur during the read-out phase and before a reset with EOI  
are trapped (pipeline). If this happens, the message at INTN cannot be deleted by EOI, i.e. INTN constantly  
remains on low. In this instance, EOI fills the excessive temperatue message from the pipeline.  
Bit 7  
0
1
No message  
(r)  
DCHI  
Interrupt through change-of-input message  
Bit 6  
IET2  
0
1
No message  
(r)  
(r)  
(r)  
Interrupt through excessive temperature level 2  
Bit 5  
IET1  
0
1
No message  
Interrupt through excessive temperature level 1  
Bit 4  
ISCI  
0
1
No message  
Interrupt through overcurrent message  
lower nibble  
overcurrent status, excessive temperature status (real time signals, at the time of readout)  
Bit 2  
0
No error message  
(r)  
(r)  
(r)  
ET2  
1
Excessive temperature level 2 (shutdown)  
Bit 1  
ET1  
0
1
No error message  
Excessive temperature level 1 (warning)  
Bit 0  
SCS  
0
1
No error message  
Overcurrent status (e.g. caused by low-side short circuit)  
Overcurrent Message (read only)  
Add.: 3  
reset entry: 00h  
Bit  
7
6
5
4
3
2
1
0
Name  
SCI7  
SCI6  
SCI5  
SCI4  
SCI3  
SCI2  
SCI1  
SCI0  
Bit 7..0  
SCI7..0  
0
1
No message  
(r)  
Output IOx has had an overcurrent state enabled for interrupt messages (short circuit)  
Read access gates off changes to the register; the register is reenabled only when reset via EOI. Any  
successive interrupts which occur during the read-out phase and before a reset with EOI are trapped by an  
interrupt pipeline. If this happens, the message at INTN cannot be deleted by EOI, i.e. INTN constantly  
remains on low. In this instance, EOI fills the overcurrent message from the pipeline.  
‘0’ is output for IOx pins in input mode.  
SCIx reports for IOx.