4.1.1.30 ABIST Failure Test Status _X_Y Registers
This register is not accessible by the user and the bit should not be set to ‘1’. It is used only during Manufac-
turing test.
Unused
Unused
DEBUG_select_1
DEBUG_select_0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
Reset Output Status (Power-on-Reset)
Address in Word Mode
Address in Byte Mode
Access Type
All ’0’s
x'8C’
x'8C to 8F’
Read/Write
Bits /
Word
Bits /
Bytes
Name
Description
Notes
31-24
23-16
15-11
10
7-0
7-0
7-3
2
Unused
Unused
DEBUG_select_1
YABistM3Fail
Select debug bus 1. Controls debug bus multiplexing.
Unused
1
1
0
ABIST Test Failure flag on M3 RAM
Normal operation
9
1
1
0
ABIST Test complete Flag
Normal operation
8
0
YABistDone
7-3
7-3
DEBUG_select_0
Select debug bus 0. Controls debug bus multiplexing.
1
Select redirect the ABIST result on the ABIST_Diagout I/O
2
2
DIAGOUT_enb_l
1
0
Y side
X side
1
0
ABIST Test Failure flag on M3 RAM
Normal operation
1
0
1
0
XABistM3Fail
XABistDone
1
0
ABIST Test complete Flag
Normal operation
1. See debug bus definition, page 120, for details.