Discontinued (9/98 - last order; 3/99 - last ship)
IBM11M2735H
IBM11M2735HB
2M x 72 DRAM MODULE
DC Electrical Characteristics (T = 0 to +70˚C, V = 3.3V ± 0.3V or V = 5.0V ± 0.5V)
A
CC
CC
Symbol
Parameter
Min. Max.
Units
mA
Notes
1, 2, 3
Operating Current
-60
—
—
810
720
ICC1
Average Power Supply Operating Current
(RAS, CAS, Address Cycling: tRC = tRC min.)
-70
Standby Current (TTL)
Power Supply Standby Current
(RAS = CAS = VIH)
ICC2
—
18
mA
mA
RAS Only Refresh Current
Average Power Supply Current, RAS Only Mode
(RAS Cycling, CAS = VIH: tRC = tRC min)
-60
-70
-60
—
—
—
810
720
450
ICC3
1, 2, 3
1, 3
Hyper Page Mode Current
ICC4
Average Power Supply Current, Hyper Page Mode
(RAS = VIL, CAS, Address Cycling: tHPC = tHPC min)
mA
-70
—
—
—
360
9
Standby Current (CMOS)
Power Supply Standby Current
(RAS = CAS = VCC - 0.2V)
ICC5
mA
mA
CAS Before RAS Refresh Current
Average Power Supply Current, CAS Before RAS Mode
(RAS, CAS, Cycling: tRC = tRC min)
-60
810
ICC6
1, 3
-70
—
720
+10
Input Leakage Current
All but RAS
-10
II(L)
IO(L)
VOH
Input Leakage Current, any input
(0.0 ≤ VIN ≤ (VCC + 0.3V)), All Other Pins Not Under Test = 0V
µA
µA
V
RAS
-50
-10
+50
+10
Output Leakage Current
(DOUT is disabled, 0.0 ≤ VOUT ≤ VCC
)
Output Level (TTL)
Output “H” Level Voltage
(IOUT = -2mA for 3.3V, or IOUT = -5mA for 5.0V)
VCC
0.4
2.4
0.0
Output Level (TTL)
Output “L” Level Voltage
(IOUT = +2mA for 3.3V, or IOUT = +4.2mA for 5.0V)
VOL
V
1. ICC1, ICC3, ICC4 and ICC6 depend on cycle rate.
2. ICC1 and ICC4 depend on output loading. Specified values are obtained with the output open.
3. Address can be changed once or less while RAS =VIL. In the case of ICC4, it can be changed once or less when CAS =VIH.
©IBM Corporation. All rights reserved.
Use is further subject to the provisions at the end of this document.
50H4199
SA14-4615-02
Revised 5/96
Page 6 of 29