IBM0118165 IBM0118165M
IBM0118165B IBM0118165P
1M x 16 10/10 EDO DRAM
Read Cycle
-50
-60
-6R
-70
Symbol
Parameter
Access Time from RAS
Units
Notes
Min. Max. Min. Max. Min. Max. Min. Max.
tRAC
tCAC
tAA
—
—
—
—
0
50
13
25
13
—
—
—
—
—
13
—
13
—
—
—
—
—
—
0
60
15
30
15
—
—
—
—
—
15
—
15
—
—
—
—
—
—
0
60
17
30
17
—
—
—
—
—
15
—
15
—
—
—
—
—
—
0
70
20
35
20
—
—
—
—
—
15
—
15
—
—
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
1, 2, 3
1, 3
2, 3
3
Access Time from CAS
Access Time from Address
tOEA
tRCS
tRCH
tRRH
tRAL
tCLZ
tOFF
tCDD
tOEZ
tOES
tORD
Access Time from OE
Read Command Setup Time
Read Command Hold Time to CAS
Read Command Hold Time to RAS
Column Address to RAS Lead Time
CAS to Output in Low-Z
0
0
0
0
4
4
0
0
0
0
25
0
30
0
30
0
35
0
3
5, 6
7
Output Buffer Turn-Off Delay
CAS to DIN Delay Time
—
13
—
5
—
15
—
5
—
15
—
5
—
15
—
5
Output Buffer Turn-Off Delay from OE
OE Setup Time Prior to CAS
OE Setup Time Prior to RAS (Hidden Refresh)
5
0
0
0
0
1. Operation within the tRCD(max.) limit ensures that tRAC(max.) can be met. tRCD(max.) is specified as a reference point only. If tRCD
is greater than the specified tRCD(max.) limit, then access time is controlled by tCAC
2. Operation within the tRAD(max.) limit ensures that tRAC(max.) can be met. tRAD(max.) is specified as a reference point only. If tRAD
is greater than the specified tRAD(max.) limit, then access time is controlled by tAA
.
.
3. Measured with the specified current load and 100pF at VOL = 0.8V and VOH = 2.0V.
4. Either tRCH or tRRH must be satisfied for a read cycle.
5. tOFF (max) and tOEZ (max) define the time at which the output achieves the open circuit condition and are not referenced to output
voltage levels.
6. tOFF is referenced from the rising edge of RAS or CAS, which ever is last.
7. Either tCDD or tOED must be satisfied.
©IBM Corporation, 1995. All rights reserved.
Use is further subject to the provisions at the end of this document.
28H4721
SA14-4223-01
Revised 12/95