Electrical Specifications
0°C ≤ TA ≤ 70°C, 4.5 V ≤ VCC ≤ 18 V, 0.5 mA ≤ IF(ON) ≤ 12 mA, 0 V ≤ VF(OFF) ≤ 0.8 V, unless otherwise
specified. All Typicals at TA = 25°C. (See note 8.)
Device
Parameter
Sym. HCPL-
Min. Typ.* Max. Units
Test Conditions
Fig. Note
2, 3 2
Current
Transfer
Ratio
CTR
2731
0731
400 1800 5000
%
IF = 0.5 mA
VCC = 4.5
VO = 0.4 V
500 1600 2600
IF = 1.6 mA
IF = 1.6 mA
2730/0730 300 1600 2600
Logic Low
Output
Voltage
VOL
2731
0731
0.1
0.1
0.2
0.1
0.4
0.4
0.4
0.4
V
IF = 1.6 mA,
IO = 8 mA
VCC = 4.5 V
1
IF = 5.0 mA,
IO = 15 mA
IF = 12 mA,
IO = 24 mA
IF = 1.6 mA,
IO = 4.8 mA
2730/0730
Logic High
Output
IOH 2731/0731
0.05
100
µA
VO = VCC =18 V IF = 0 mA
2
Current
2730/0731
0.1
1.2
250
3
VO = VCC = 7 V
Logic Low
Supply
ICCL 2731/0731
mA VCC =18V IF1 =IF2 =1.6 mA
V = V = Open
5
5
4
01
02
Current
2730/0730
0.9
VCC = 7 V
Logic High
Supply
Current
ICCH 2731/0731
0.005
20
µA
V
VCC =18V IF1 = IF2 = 0 mA,
V = V = Open
VCC =7V
01
02
2730/0730
VF
0.004
1.4
Input
1.7
TA = 25°C
Forward
Voltage
1.75
IF = 1.6 mA
IR = 10 µA, TA = 25°C
Input
BVR
5.0
V
2
2
Reverse
Breakdown
Voltage
Temperature
Coefficient
of Forward
Voltage
∆VF
∆TA
-1.8
60
mV/°C IF = 1.6 mA
Input
CIN
pF
f = 1 MHz, VF = 0
Capacitance
*All typical values at TA = 25°C and VCC = 5 V, unless otherwise noted.
1-115