RFM68CW
RFM68CW
2. Electrical Characteristics
2.1. ESD Notice
The RFM68CW is an electrostatic discharge sensitive device. It satisfies Class 2 of the JEDEC standard
JESD22-A114-B (human body model) on all pins.
2.2. Absolute Maximum Ratings
Stresses above the values listed below may cause permanent device failure. Exposure to absolute maximum ratings for
extended periods may affect device reliability.
Table 2 Absolute Maximum Ratings
Symbol
Description
Min
Max
Unit
VDDmr
Tmr
Supply Voltage
-0.5
-55
-55
-55
3.9
115
125
150
V
Temperature
° C
° C
° C
Tjunc
Tstor
Junction Temperature
Storage Temperature
2.3. Operating Range
Operating ranges define the limits for functional operation and the parametric characteristics of the device as described in
this section. Functionality outside these limits is not implied.
Table 3 Operating Range
Symbol
Description
Min
Max
Unit
VDDop
Top
Supply voltage
1.8
-40
-
3.7
85
25
V
Operational temperature range
Load capacitance on digital ports
° C
pF
Clop
5