Hazardous Location
5/8 INCH (M16*) INTRINSICALLY SAFE VRS SENSORS (All dimensions for reference only. mm/[in])
*Contact Honeywell for availability of metric mounting thread versions.
When properly installed using the intrinsic safety protection method connected per the control drawings on pages 6 and 7, catalog
listings 3042A is intrinsically safe for hazardous locations as follows:
Class I, Groups A, B, C, D.
This product has been tested to and meets the requirements of applicable U.S. and Canadian specifications for the locations
described above.
General Specifications
Test Condition Specifications
Parameter Characteristic
Surface speed 25 m/s
[1000 in/s]
8 DP
Parameter
Characteristic
Parameter
Characteristic
Min. output voltage 30 Vp-p
Inductance
26 mH max.
Coil resistance
150 Ohm
Gear pitch range
16 DP (module 1.58)
or coarser
Gear
(module 3.17)
0,127 mm
[0.005 in]
Pole piece
diameter
Min. surface
speed
3,9 mm [0.156 in]
0,38 m/s [15 in/s] typ.
Optimum actuator 12 DP (module 3.17)
ferrous metal gear
Air gap
Max. operating
frequency
40 kHz typ.
Load
100 kOhm
resistance
Operating temp.
range
-55 ºC to 120 ºC
[-67 ºF to 250 ºF]
Vibration
N/A
Mounting thread
5/8-18 UNF-2A
Termination
MS3106 connector
Catalog
Listing
3042A
Weight
70 g [2.5 oz]
8,0
36.5
[1.437]
28,12
[1.107]
19,05
[0.750]
[0.312]
0,76
[0.030]
B
+
A
-
Ø18,29
[0.720]
Ø13,84
[0.545]
‘
4
www.honeywell.com/sensing