HI-3200, HI-3201  
Current Sequence number  
TRANSMIT SEQUENCE POINTERS 0 -3  
(Address 0x802C - 0x802F)  
7
6
5
4
3
2
1
0
LSB  
MSB  
The transmit sequence pointer is set to zero on Master  
This continues until the programmed sequence is  
complete. The sequence pointer is then reset to the  
beginning of the descriptor table and program execution  
begins as soon the channel repetition rate counter time  
elapses.  
Reset. Once the Control Register RUN / STOP bit goes  
high, sequence execution begins at sequence count  
zero. After the first word is sent, the pointer is  
incremented by one descriptor (counts descriptor  
frames).  
Channel Repetition Period  
REPETITION RATE REGISTER  
(Address 0x801C - 0x801F)  
7
6
5
4
3
2
1
0
LSB  
MSB  
The Repetition rate register value defines the time  
interval between successive starts of the programmed  
transmit sequence for each ARINC 429 transmit channel.  
The value is set in binary, with the LSB representing 10  
ms. Repetition rate time periods may therefore be set  
from 0 ms to 2.55 seconds  
When the Repetition Rate counter is programmed to zero  
(default), the transmit sequence shall execute one time  
only. A zero - to - one transition of the RUN/STOP bit will  
cause the transmit sequence to start. One-time execution  
of the sequencer is useful when transmitting ARINC 429  
words directly from the host CPU. One or more  
immediate-mode descriptors can be written into the  
sequence table, transmitted, and then refreshed for the  
next cycle.  
If the repetition rate is shorter than the minimum time  
needed to transmit all ARINC 429 words in the sequence  
(but not zero), the transmit sequence will begin again  
immediately if the Control Register SKIP bit is a zero. If  
the SKIP bit is a one, the sequencer will wait until the  
next rollover of the Repetition Rate Counter before  
starting a new cycle.  