HT48R063/064/065/066/0662/067
Test Conditions
Conditions
Symbol
Parameter
Min.
Typ.
Max.
Unit
VDD
SCOMC, ISEL[1:0]=00
SCOMC, ISEL[1:0]=01
SCOMC, ISEL[1:0]=10
SCOMC, ISEL[1:0]=11
17.5
35
25.0
50
32.5
65
mA
mA
ISCOM
SCOM Operating Current
5V
70
100
200
130
260
mA
140
mA
VSCOM
VDD/2 Voltage for LCD COM
5V No load
0.475 0.500 0.525
VDD
Note: The standby current (ISTB1~ISTB3) and IDD4 are measured with all I/O pins in input mode and tied to VDD
.
A.C. Characteristics
Ta=25°C
Unit
Test Conditions
Conditions
2.2V~5.5V
Symbol
Parameter
Min.
Typ.
Max.
VDD
32
4000
8000
12000
+2%
+2%
+2%
+5%
+5%
+5%
kHz
kHz
¾
¾
¾
4
fSYS
System Clock
3.0V~5.5V
32
¾
4.5V~5.5V
32
kHz
3V/5V
3V/5V
5V
MHz
MHz
MHz
MHz
MHz
MHz
Ta=25°C
-2%
-2%
-2%
-5%
-5%
-5%
8
Ta=25°C
12
4
Ta=25°C
3V/5V
3V/5V
5V
Ta=0~70°C
Ta=0~70°C
Ta=0~70°C
8
12
2.2V~
3.6V
4
4
+8%
+8%
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Ta=0~70°C
-8%
-8%
3.0V~
5.5V
Ta=0~70°C
System Clock
(HIRC)
fHIRC
3.0V~
5.5V
8
+8%
Ta=0~70°C
-8%
4.5V~
5.5V
12
4
+8%
Ta=0~70°C
-8%
2.2V~
3.6V
+12%
+12%
+12%
+12%
Ta= -40°C~85°C
Ta= -40°C~85°C
Ta= -40°C~85°C
Ta= -40°C~85°C
-12%
-12%
-12%
-12%
3.0V~
5.5V
4
3.0V~
5.5V
8
4.5V~
5.5V
12
5V
5V
4
4
+2%
+5%
MHz
MHz
Ta=25°C, R=120kW *
-2%
-5%
Ta=0~70°C, R=120kW *
Ta= -40°C~85°C,
R=120kW *
fERC
System Clock (ERC)
5V
4
4
+7%
MHz
MHz
-7%
2.2V~ Ta= -40°C~85°C,
+11%
-11%
5.5V
R=120kW *
Rev. 1.10
11
June 9, 2009