MB90480/485 Series
• Note of SDA and SCL set-up time
SDA
Input data set-up time
SCL
6 tcp
Note : The rating of the input data set-up time in the device connected to the bus cannot be satisfied depending on
the load capacitance or pull-up resistor.
Be sure to adjust the pull-up resistor of SDA and SCL if the rating of the input data set-up time cannot be
satisfied.
• Timing definition
SDA
tBUS
tHDSTA
tSUDAT
tLOW
SCL
tHDSTA
tSUSTA
tHIGH
tSUSTO
tHDDAT
fSCL
106