MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90
■ DC CHARACTERISTICS
Parameter
Symbol
Parameter Description
Test Conditions
Min.
Max.
Unit
ILI
Input Leakage Current
Output Leakage Current
VIN = VSS to VCC, VCC = VCC Max.
VOUT = VSS to VCC, VCC = VCC Max.
–1.0
–1.0
+1.0
+1.0
µA
µA
ILO
A9, OE, RESET Inputs Leakage VCC = VCC Max.
ILIT
—
—
50
µA
Current
A9, OE, RESET = 12.5 V
Byte
38
45
50
ICC1
ICC2
VCC Active Current (Note 1)
VCC Active Current (Note 2)
CE = VIL, OE = VIH
CE = VIL, OE = VIH
mA
Word
—
—
mA
mA
VCC = VCC Max., CE = VIH,
RESET = VIH
1
5
1
5
ICC3
VCC Current (Standby)
VCC = VCC Max., CE = VCC ± 0.3 V,
RESET = VCC ± 0.3 V
—
—
—
µA
mA
µA
VCC = VCC Max.,
RESET = VIL
ICC4
VCC Current (Standby, Reset)
VCC = VCC Max.,
RESET = VSS ± 0.3 V
VIL
VIH
Input Low Level
Input High Level
—
—
–0.5
2.0
0.8
V
V
VCC + 0.5
Voltage for Autoselect and
Sector Protection
VID
—
11.5
12.5
V
(A9, OE, RESET) (Note 3, 4)
VOL
VOH1
VOH2
VLKO
Output Low Voltage Level
Output High Voltage Level
Low VCC Lock-Out Voltage
IOL = 5.8mA, VCC = VCC Min.
IOH = –2.5 mA, VCC = VCC Min.
IOH = –100 µA
—
2.4
0.45
—
V
V
V
V
VCC – 0.4
3.2
—
—
4.2
Notes: 1. The ICC current listed includes both the DC operating current and the frequency dependent component
(at 6 MHz). The frequency component typically is 2 mA/MHz, with OE at VIH.
2. ICC active while Embedded Algorithm (program or erase) is in progress.
3. Applicable to sector protection function.
4. (VID – VCC) do not exceed 9 V.
25