Freescale Semiconductor, Inc.
FLASH-2 Memory
BLK0 — Block Erase Control Bit
This read/write bit together with BLK1 allows erasing of blocks of
varying size. See 5.6 FLASH Erase Operation for a description of
available block sizes.
HVEN — High-Voltage Enable Bit
This read/write bit enables the charge pump to drive high voltages for
program and erase operations in the array. HVEN can be set only if
either PGM = 1 or ERASE = 1 and the proper sequence for
program/margin read or erase is followed.
1 = High voltage enabled to array and charge pump on
0 = High voltage disabled to array and charge pump off
MARGIN — Margin Read Control Bit
This read/write bit configures the memory for margin read operation.
MARGIN cannot be set if the HVEN = 1. MARGIN will automatically
return to unset (0) if asserted when HVEN = 1.
1 = Margin read operation selected
0 = Margin read operation unselected
ERASE — Erase Control Bit
This read/write bit configures the memory for erase operation.
ERASE is interlocked with the PGM bit such that both bits cannot be
set at the same time.
1 = Erase operation selected
0 = Erase operation unselected
PGM — Program Control Bit
This read/write bit configures the memory for program operation.
PGM is interlocked with the ERASE bit such that both bits cannot be
set at the same time.
1 = Program operation selected
0 = Program operation unselected
Technical Data
MC68HC908AS60 — Rev. 1.0
FLASH-2 Memory
For More Information On This Product,
Go to: www.freescale.com