August 27, 1998  
GENERAL RELEASE SPECIFICATION  
18.8 CONTROL TIMING  
Characteristic  
Symbol  
Min  
Max  
Unit  
Frequency of Oscillation (OSC)  
Crystal Oscillator Option  
External Clock Source  
f
f
f
f
0.1  
DC  
1.5  
0.5  
4.2  
4.2  
5.8  
4
MHz  
MHz  
MHz  
kHz  
OSC  
OSC  
OSC  
OSC  
2
Internal VCO (SCLK = 0)  
2
Internal VCO (SCLK = 1)  
Internal Operating Frequency, Crystal or External Clock (f  
Crystal Oscillator Option  
/2)  
OSC  
f
f
0.05  
DC  
2.1  
2.1  
MHz  
MHz  
OP  
OP  
External Clock Source  
Cycle Time  
Crystal Oscillator or External Clock source  
t
476  
ns  
CYC  
Timer  
Resolution  
Input Capture (TCAP) pulse width  
t
4.0  
284  
t
t
RESL  
, t  
CYC  
ns  
t
t
TH TL  
Interrupt Pulse Width Low (Edge-Triggered)  
Interrupt Pulse Period  
t
284  
see note 3  
110  
ns  
ILIH  
t
ILIL  
CYC  
OSC1 Pulse Width (external clock input)  
,t  
ns  
OH OL  
Voltage Comparator Switching Time  
(10 mV overdrive, either input)  
t
10  
µs  
PROP  
Voltage Comparator Power Up Delay  
(Bias Circuit already powered up)  
t
100  
10  
µs  
µs  
DELAY  
External Capacitor Switching Time (I  
to I  
)
t
PROP  
DIS  
RAMP  
External Capacitor Current Source Power Up Delay  
(Bias Circuit already powered up)  
t
t
100  
100  
µs  
µs  
DELAY  
Bias Circuit Power Up Delay  
DELAY  
NOTES:  
1.  
V
=5V ± 10%, V = 0 V, T T T , unless otherwise noted.  
DD SS L A H  
2. Due to process variations, operating voltages, and temperature requirements, the quoted VCO fre-  
quencies are typical limits, and should be treated as reference only. It is the user’s responsibility to  
ensure that the resulting internal operating frequency meets user’s requirement by setting the appropri-  
ate value in the VCO Adjust Register.  
3. The minimum period t  
should not be less than the number of cycle times it takes to execute the inter-  
ILIL  
rupt service routine plus 21 t  
.
CYC  
MC68HC05SB7  
REV 2.1  
ELECTRICAL SPECIFICATIONS  
MOTOROLA  