FUNCTIONAL DEVICE OPERATIONS  
OPERATIONAL MODES  
Interrupt  
Control  
VDD  
HVSE  
VDD  
Module  
PWMIN  
PWMHSx  
VS2  
MOD1:2  
High Side - Driver  
charge pump  
open load detection  
current limitation  
on/off  
HSx  
Control  
HSxOP  
Status  
overtemperture shutdown (interrupt maskable)  
high voltage shutdown (maskable)  
HSxCL  
HSx  
Wakeup  
Module  
Figure 17. High Side Drivers HS1 and HS2  
Open Load Detection  
Interrupt Control Module. The shutdown is indicated as HS  
Interrupt in the Interrupt Source Register (ISR).  
Each high side driver signals an open load condition if the  
current through the high side is below the open load current  
threshold.  
A thermal shutdown of the high side drivers is indicated by  
setting all HSxOP and HSxCL bits simultaneously.  
If the bit HSM is set in the Interrupt Mask Register (IMR),  
then an interrupt (IRQ) is generated.  
The open load condition is indicated with the bits HS1OP  
and HS2OP in the High Side Status Register (HSSR).  
A write to the High Side Control Register (HSCR), when  
the over-temperature condition is gone, will re-enable the  
high side drivers.  
Current Limitation  
Each high side driver has an output current limitation. In  
combination with the over-temperature shutdown the high-  
side drivers are protected against over-current and short-  
circuit failures.  
High-voltage Shutdown  
In case of a high voltage condition and if the high voltage  
shutdown is enabled (bit HVSE in the Mode Control Register  
(MCR) is set) both high side drivers are shut down.  
When the driver operates in the current limitation area, it is  
indicated with the bits HS1CL and HS2CL in the HSSR.  
A write to the High Side Control Register (HSCR), when  
the high voltage condition is gone, will re-enable the high side  
drivers.  
Note: If the driver is operating in current limitation mode,  
excessive power might be dissipated.  
Over-temperature Protection (HS Interrupt)  
Sleep And Stop Mode  
Both high side drivers are protected against over-  
temperature. In case of an over-temperature condition both  
high side drivers are shut down and the event is latched in the  
The high side drivers can be enabled to operate in Sleep  
and Stop Mode for cyclic sensing. Also see Table 5,  
Operating Modes Overview.  