PIN CONNECTIONS  
Table 1. 33186 Pin Description(continued)  
Pin  
Name  
Description  
The Pins 4 and 5 are internally connected. These Pins supply the left high side and the analog/logic  
part of the device.  
4, 5, 16  
VBAT  
The Pin 16 supplies the right high side and the charge pump.  
The Pins 4, 5 and 16 should be connected together on the printed circuit board with connections as  
short as possible.  
Supervision and protection functions  
a) Supply voltage supervision  
The supply voltage is supervised. If it is below its specific threshold, the power stages are switched  
in tristate and the status flag is switched low.  
If the supply voltage is over the specific threshold again, the power stage switches independently  
into normal operation, according to the input Pins and the status flag is reset.  
b) Thermal supervision  
In case of overtemperature, the power stages are switched in tristate independent of the inputs  
signals and the status flag is switched low.  
If the level changes from high to low on DI1 (IN1) or low to high on DI2 (IN2), the output stage  
switches on again if the temperature is below the specified limit.The status-flag is reset to high level  
(Pin names in brackets refer to coding Pin = VCC).  
c) Supervision of overcurrent on high sides and low sides  
In case of over-current detection, the power stages are switched in tristate independent of the inputs  
signals and the status flag is set.  
If the level changes from high to low on DI1 (IN1) or low to high on DI2 (IN2) the output stage  
switches on again and the status flag is reset to high level (Pin names in brackets refer to coding Pin  
= VCC).  
The output stage switches into the mode defined by the inputs Pins provided, and/if the temperature  
is below the specified limits.  
d) Current limiting on low sides  
The maximum current which can flow under normal operating conditions is limited to Imax = 6,5 A  
+/- 20%. When the maximum current value is reached, the output stages are switched tristate for a  
fixed time. According to the time constant the current decreases until the next switch on occurs. See  
page 8 for schematics.  
Charge Pump output Pin  
17  
CP  
A filtering capacitor (up to 33 nF) can be connected between Pin 17 and Gnd. Device can operate  
without external capacitor, although Pin 17 decoupling capacitor help in noise reduction and allows  
the device to perform a maximum speed, timing and PWM frequency.  