PIN CONNECTIONS
PIN CONNECTIONS
PIN CONNECTIONS
AGND
SF
1
2
NC
IN2
20
19
18
17
16
IN1
3
DI1
VBAT
VBAT
OUT1
OUT1
CP
4
VBAT
5
6
5
1
OUT2
7
14 OUT2
3
1
COD
PGND
PGND
8
DI2
9
12
11
PGND
PGND
10
Metal slug is connected to power ground
(Top View)
Figure 3. 33186 Pin Locations
Table 1. 33186 Pin Description
Pin
Name
Description
Power Ground. All the ground are connected together, they should be connected as short as
possible on the PCB.
9, 10, 11, 12
Metal slug
PGND
Analog ground. All the ground are connected together, they should be connected as short as
possible on the PCB.
1
AGND
Open drain output, active low. Is set according to the truth table. When a fault appears, SF changes
typically in less than 100 ms.
2
Output
Status flag (SF)
Voltage controlled inputs with hysteresis
3,13
Inputs IN1, IN2,
DI1, DI2, COD
18, 19
When not connected or connected to GND, a stored failure will be reset by change of the voltage-
level on DI1 or DI2.
8
COD
When connected to VCC, the disable Pin DI1 and DI2 are inactive. A stored failure will be reset by
change of the voltage-level on IN1 or IN2.
H-Bridge outputs with integrated free-wheeling diodes.
6, 7, 14, 15
OUT1, OUT2
33186
Analog Integrated Circuit Device Data
Freescale Semiconductor
3