F81867
PSON# de-active time select for voltage protection.
00: PSON# tri-state 0.5 sec and then inverted of S3# when over voltage or
under voltage occurred.
01: PSON# tri-state 1 sec and then inverted of S3# when over voltage or
3-2
PU_TIME
R/W
VBAT
2’h1 under voltage occurred.
10: PSON# tri-state 2 sec and then inverted of S3# when over voltage or
under voltage occurred.
11: PSON# tri-state 4 sec and then inverted of S3# when over voltage or
under voltage occurred.
VP_EN_DELAY could set the delay time to start voltage protecting after
VDD power is ok when OVP_MODE is 1. (OVP_MODE is strapped by
RTS1# pin)
2’h2 00: bypass
01: 50ms
1-0
VP_EN_DELAY
R/W
VBAT
10: 100ms
11: 200ms
Voltage1 PME# Enable Register ⎯ Index 14h
Bit
Name
R/W Reset Default
Description
Reserved
7-2
Reserved
-
-
5VSB
-
0
0
-
A one enables the corresponding interrupt status bit for PME# interrupt.
Set this bit 1 to enable PME# function for VIN1.
Reserved
1
0
EN_V1_PME
Reserved
R/W
-
Voltage1 Interrupt Status Register ⎯ Index 15h
Bit
Name
R/W Reset Default
Description
Reserved
7-2
Reserved
--
-
5VSB
-
0
0
This bit is set when the VIN1 is over the high limit. Write 1 to clear this bit,
write 0 will be ignored.
Reserved
1
0
V1_ EXC _STS
Reserved
R/W
-
-
Voltage1 Exceeds Real Time Status Register 1 ⎯ Index 16h
Bit
Name
R/W Reset Default
Description
7-2
Reserved
--
RO
--
-
5VSB
-
0
0
0
Reserved
A one indicates VIN1 exceeds the high limit. A zero indicates VIN1 is in the
safe region.
1
0
V1_EXC
Reserved
Reserved
64
Dec, 2011
V0.12P