F81867
OVT and Alert Output Enable Register 1 ⎯ Index 66h
Bit
Name
R/W Reset Default
Description
7
Reserved
R/W
0
Reserved
-
Enable temperature 2 alert event (asserted when temperature over high
6
EN_T2_ALERT
R/W 5VSB
R/W 5VSB
0
limit)
Enable temperature 1 alert event (asserted when temperature over high
limit)
5
4
EN_T1_ALERT
EN_T0_ALERT
0
0
Enable temperature 0 alert event (asserted when temperature over high
limit)
R/W
R/W
5VSB
-
3
2
1
0
Reserved
0
0
1
0
Reserved
EN_T2_OVT
EN_T1_OVT
EN_T0_OVT
R/W 5VSB
R/W 5VSB
R/W 5VSB
Enable over temperature (OVT) mechanism of temperature2.
Enable over temperature (OVT) mechanism of temperature1.
Enable over temperature (OVT) mechanism of temperature0.
Temperature Sensor Type Register ⎯ Index 6Bh
Bit
Name
R/W Reset Default
Description
7-4
Reserved
RO
RO
0
0
Reserved
Reserved
-
-
3
2
Reserved
0: TEMP2 is connected to a thermistor.
1: TEMP2 is connected to a BJT. (default)
0: TEMP1 is connected to a thermistor
1: TEMP1 is connected to a BJT.(default)
T2_MODE
R/W
5VSB
1
1
0
T1_MODE
Reserved
R/W
R
1
0
5VSB
-
Reserved
TEMP1 Limit Hystersis Select Register ⎯ Index 6Ch
Bit
Name
R/W Reset Default
Description
Limit hysteresis. (0~15ºC)
7-4
TEMP1_HYS
R/W
R/W
4h
4h
5VSB
5VSB
Temperature and below the (boundary – hysteresis).
Limit hysteresis. (0~15ºC)
3-0
TEMP0_HYS
Temperature and below the (boundary – hysteresis).
TEMP2 and TEMP3 Limit Hystersis Select Register ⎯ Index 6Dh
Bit
Name
R/W Reset Default
Description
7-4
Reserved
R
0
Reserved
-
Limit hysteresis. (0~15ºC)
3-0
TEMP2_HYS
R/W 5VSB
4h
Temperature and below the (boundary – hysteresis ).
60
Dec, 2011
V0.12P